Stephanie Panzer1, Sieglinde Ketterl2, Roxane Bicker3
1Department of Radiology, Trauma Center Murnau, Prof-Küntscher-Strasse 8, D-82418 Murnau, Germany; Institute of Biomechanics, Trauma Center Murnau and Paracelsus Medical University, Salzburg, Austria, Prof-Küntscher-Strasse 8, D-82418 Murnau, Germany.
Objective:
The purpose of this study was to develop and provide recommendations for computed tomography (CT) examinations of human mummies.
Materials And Methods:
Based on theoretical considerations and examples, recommendations for use are provided for scanning and image reconstruction parameters. Four examples are presented to illustrate the effect of different CT parameters on image quality.
Results:
The use of appropriate scanning parameters (detector collimation, pitch factor, rotation time) is known to improve image quality; technical considerations favor using lower tube voltage and higher tube current values for the purposes of scanning of human mummies. The use of appropriate image reconstruction parameters (slice thickness, increment, field of view, reconstruction filters) are the basis for individual reconstructions for the purpose of evaluation, documentation, illustration and data storage.
Conclusions:
Downsizing the field of view to the region of interest as done in the clinical radiological routine represents one major tool to improve image quality.
Significance:
The provided recommendations should improve CT image quality in mummy studies as well as the handling of image data for reconstructions and storage.
Limitations:
The recommendations for CT scanning parameters and image reconstructions were written with relatively new generation CT scanners in mind. Only a few examples of use were chosen and image quality assessment was performed subjectively and not by quantitative measurements.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Newton's Third Law: Examples
Free Body Diagrams: Examples
Theoretical Approaches to Psychological Disorder
Biological approach
The biological approach posits that internal, organic factors are the primary causes of such disorders. This perspective emphasizes brain structure and function, genetic predispositions, and neurotransmitter imbalances. For example, schizophrenia has been associated with both genetic...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Design Consideration
The factor of safety is another key...
Leaky Scanning