Related Experiment Video
Updated: Jan 21, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Clinical and Radiological Evaluation of Patients Undergoing Distal Radio Osteosynthesis with Locking
Jurandyr de Abreu Câmara Filho1, Saulo Fontes Almeida1
1Serviço Clínico de Ortopedia e Traumatologia, Hospital Naval Marcílio Dias, Rio de Janeiro, RJ, Brasil.
Abstract:
Objective The objective of the present work was to perform a retrospective study based on the medical files and radiographs of the patients, as well as on the socioeconomic data of the patients submitted to distal radio osteosynthesis with locking plates, evaluating them clinically and radiographically. Methods The postoperative period was evaluated clinically and radiologically in the orthopedics and traumatology clinic service of our hospital between 2016 and 2017. Results In the radiographic evaluation, we found 22 (75.86%) excellent results, 6 (20.69%) good results, and 1 (3.45%) regular result. In the clinical evaluation, the ulnar deviation obtained a mean of 28.40, a standard deviation (SD) of 3.0 and a coefficient of variation of 10.56%. The radial deviations averaged 22.93, with a SD of 2.2 and a coefficient of variation of 9.59%. The range of motion in flexion obtained a mean of 59.43, a SD of 9.86 and a coefficient of variation of 16.59%. The extension obtained a mean of 53.83, a SD of 5.09 and a coefficient of variation of 9.46%. Conclusion We have concluded that there is statistical correlation between clinical and radiographic data, and that the locking plate is a treatment method with a high success rate in the surgical procedure of distal radius fractures.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Radiological Investigation I: X-ray and CT
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Hypertension III: Clinical Manifestations and Diagnostic Studies