Whole Breast and Lymph Node Irradiation using Halcyon™ 2.0 Utilizing Automatic Multi-isocenter Treatment Delivery and
Michele M Kim1, Chris Kennedy1, Ryan Scheuermann1
1Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA.
Abstract:
The HalcyonTM is a newly introduced platform to provide a simplified high-throughput workflow. A substantial fraction of patients treated with radiation are receiving breast irradiation. The Halcyon has a smaller maximum field size (28 x 28 cm2) compared to traditional C-arm linacs, limiting treatment of larger breast fields. With the use of autofeathering and linked multiple isocenters, non-divergent beams can be used to treat whole breast with large mid-tangent separation. In this case report, a multiple isocenter whole breast treatment with nodal involvement is described with the Halcyon 2.0 platform. The patient was simulated with the same immobilization techniques as used for C-arm linac treatments. The treatment planning time was around 20-30 minutes, which is similar to traditional planning for C-arm linacs, and dosimetric analysis resulted in satisfactory dose-volume histogram (DVH) parameters that met all planning objectives. Treatment times were shorter with an average of 9:32 minutes from the beginning of imaging to the end of treatment and a total in-room time of around 15 minutes per fraction. The use of multiple isocenters for the extended treatment field created a half-beam block type field arrangement, which has been previously reported to produce superior dosimetry results at the supraclavicular-tangents junction area.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Imaging Studies III: Computed Tomography
Automatic Processing and Automatic Social Behavior
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Classical Conditioning in Daily Life
John B. Watson and Rosalie Rayner famously demonstrated the development of fear through classical conditioning in their experiment with Little Albert. They paired the...