Flow-splitting-based computation of outlet boundary conditions for improved cerebrovascular simulation in multiple
Sylvia Saalfeld1,2, Samuel Voß3,4, Oliver Beuing5,4
1Department of Simulation and Graphics, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany. sylvia.saalfeld@ovgu.de.
Purpose:
Image-based hemodynamic simulations have great potential for precise blood flow predictions in intracranial aneurysms. Due to model assumptions and simplifications with respect to boundary conditions, clinical acceptance remains limited.
Methods:
Within this study, we analyzed the influence of outflow-splitting approaches on multiple aneurysm studies and present a new outflow-splitting approach that takes the precise morphological vessel cross sections into account. We provide a detailed comparison of five outflow strategies considering eight intracranial aneurysms: zero-pressure configuration (1), a flow splitting inspired by Murray's law with a square (2) and a cubic (3) vessel diameter, a flow splitting incorporating vessel bifurcations based on circular vessel cross sections (4) and our novel flow splitting including vessel bifurcations and anatomical vessel cross sections (5). Other boundary conditions remain constant. For each simulation and each aneurysm, we conducted an evaluation based on common hemodynamic parameters, e.g., normalized wall shear stress and inflow concentration index.
Results:
The comparison of five outflow strategies for image-based simulations shows a large variability regarding the parameters of interest. Qualitatively, our strategy based on anatomical cross sections yields a more uniform flow rate distribution with increased aneurysm inflow rates. The commonly used zero-pressure approach shows the largest variations, especially for more distal aneurysms. A rank ordering of multiple aneurysms in one patient might still be possible, since the ordering appeared to be independent of the outflow strategy.
Conclusions:
The results reveal that outlet boundary conditions have a crucial impact on image-based blood flow simulations, especially for multiple aneurysm studies. We could confirm the advantages of the more complex outflow-splitting model (4) including an incremental improvement (5) compared to strategies (1), (2) and (3) for this application scenario. Furthermore, we discourage from using zero-pressure configurations that lack a physiological basis.
Related Concept Videos
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
Magnetostatic Boundary Conditions
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Boundary Conditions for Current Density
Electrostatic Boundary Conditions in Dielectrics
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity....
¹H NMR Signal Multiplicity: Splitting Patterns