A new fast algorithm to achieve the dose uniformity around high dose rate brachytherapy stepping source using
1Department of Physics (LPM-ERM), Faculty of Sciences and Techniques, Sultan Moulay Slimane University, B.P. 523, 23000, Béni-Mellal, Morocco.
Abstract:
The dose optimization algorithm based on anatomical points is developed to produce rapidly uniform doses over target distances generated on the target volume edges in high-dose-rate (HDR) brachytherapy stepping source application for a treatment length of 6 cm. Monte Carlo modeling of the 60Co HDR brachytherapy source and the surrounding medium were performed using PHITS code. The source dwell times were optimized using Tikhonov regularization in order to obtain uniform dose distribution at the anatomical points located at predefined target distances. The computed dose rates at distances from 0.25 up to 20 cm away from the source were first verified with the literature data sets. Then, the simulation results of the optimization process were compared to the calculations of commercial treatment planning system (TPS) SagiPlan. As a result, the dose uniformity was observed in the isodose curves at the target distances of 10 and 15 mm of the treatment length and the prescribed dose achieved the anatomical points uniformly. The algorithm developed in the present study can be applied for achieving the dose uniformity around the brachytherapy stepping source as a quicker tool for different treatment lengths and different target distances while maintaining the high quality of the treatment plans, saving time by avoiding the manual isodose shaping and then better suitable treatment for patients.
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dose-Response Relationship: Overview