Related Experiment Video
Updated: Jan 21, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Static and dynamic pupil characteristics in pseudoexfoliation syndrome and glaucoma
Kemal Tekin1, Hasan Kiziltoprak2, Mehmet Ali Sekeroglu2
1Opthalmology Department, Ercis State Hospital, Van, Turkey.
Background:
To compare the static and dynamic pupillometry measurements in patients with pseudoexfoliation syndrome (PES), patients with pseudoexfoliation glaucoma (PEG) and age-matched healthy subjects using an automatic quantitative pupillometry system.
Methods:
This prospective, cross-sectional study consisted of 40 patients with PES, 30 patients with PEG and 43 control subjects. Static pupillometry measurements including scotopic pupil diameter, mesopic pupil diameter, low photopic pupil diameter, and high photopic pupil diameter were undertaken. Subsequently, dynamic pupillometry measurements including resting diameter, amplitude of pupil contraction, latency of pupil contraction, duration of pupil contraction, velocity of pupil contraction, latency of pupil dilation, duration of pupil dilation, and velocity of pupil dilation were undertaken. These measurements were compared between the groups.
Results:
The scotopic, mesopic, and low photopic pupil diameter values were statistically significantly lower in patients with PES and PEG compared with controls (p < 0.001). However, these parameters were similar between the patients with PES and PEG (p > 0.05). The mean values of high photopic pupil diameter were similar within all groups (p = 0.54). The amplitude of pupil contraction values of the patients with PEG was statistically significantly lower than the patients with PES and the controls (p < 0.05). Patients with PES also had significantly lower amplitude of pupil contraction values compared with controls (p < 0.001). Additionally, the velocity of pupil contraction values was statistically significantly higher in control subjects when compared to the patients with PES and PEG (p < 0.05).
Conclusion:
This study demonstrated that accumulation of pseudoexfoliative material can cause alterations in static and dynamic pupillary characteristics and the progression from PES to PEG may be associated with reduced amplitude of pupil contraction values.
More Related Videos
12:48In Vivo Dynamics of Retinal Microglial Activation During Neurodegeneration: Confocal Ophthalmoscopic Imaging and Cell Morphometry in Mouse Glaucoma
Published on: May 11, 2015
08:31Versatility of Protocols for Resistance Training and Assessment Using Static and Dynamic Ladders in Animal Models
Published on: December 17, 2021
Related Concept Videos
Static, Stagnation, Dynamic and Total Pressure
Glaucoma: Overview
Static Equilibrium - I
Static Equilibrium - II
Static Friction
For example, consider a scenario where a truck is connected to a car by a rope, ready to tow it along a road. When no external force is applied by the truck, the car remains stationary and is said to be in static equilibrium. In this case, the forces acting on the car, such as gravity and the...
Characteristics of Life