Design of a lightweight magnetizer to enable a portable circumferential magnetic flux leakage detection system
Hong Quang Pham1, Van Sy Le1, Minh Hung Vu1
1PetroVietnam University, 762 Cach Mang Thang Tam Road, Baria City 790000, Vietnam.
Abstract:
We proposed a lightweight magnetizer toward the realization of a portable circumferential magnetic flux leakage (MFL) inspection tool for the detection of longitudinal defects with a linear motion between pipes and the inspection tool. The proposed magnetizer consists of four permanent magnetic poles constructing a configuration in which the like poles are separated by a θ angle ranging from 30° to 60° and the opposite poles are separated by a supplemental angle of θ. The distribution of the magnetic field generated by this magnetizer and caused by defects was studied by finite element methods as well as by experimental measurements. The results reveal that the new magnetizer has advantages of high amplitude and good uniformity of magnetic field over the state-of-the-art ones with configurations of two facing poles or quadrupole geometries. With the new magnetizer, the theoretical and experimental results show that the magnetization in the pipe increases slightly with the θ angle, but the uniformity of magnetization in the pipe and the magnetic field on the surface of pipe decrease dramatically with this angle. So, the optimum angle θ is proposed at around 30°-40°. The finite element calculation and the measurements of the MFL signal caused by artificial defects evidence the capabilities in detecting shallow longitudinal defects of the MFL inspection tool with our novel magnetizer.
Related Concept Videos
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Declination
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...