Related Experiment Video
Updated: Jan 21, 2026

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
Published on: January 3, 2016
Frequency-difference beamforming in the presence of strong random scattering
Alexander S Douglass1, David R Dowling1
1Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA.
Abstract:
Frequency-difference beamforming [Abadi, Song, and Dowling (2012). J. Acoust. Soc. Am. 132, 3018-3029] is a nonlinear, out-of-band signal processing technique used to beamform non-zero bandwidth signals at below-band frequencies. This is accomplished with the frequency-difference autoproduct AP(Δω)=P(ω2)P*(ω1), a quadratic product of complex field amplitudes that mimics a genuine field at the difference frequency, Δω=ω2-ω1. For frequency-difference beamforming, AP(Δω) replaces the in-band complex field in the conventional beamforming algorithm. Here, the near-field performance of frequency-difference beamforming is evaluated in the presence of 1 to 30 high-contrast spherical scatterers with radius a placed between, and in the plane defined by the source and a 12-element linear receiving array with element spacing d. Based on the center frequency wave number, k, of the 150-200 kHz frequency sweep source signal, the scatterers are large, ka ≈ 15; the array is sparse, kd = 37; and the average source-to-receiver distance is up to 4.3 mean-free-path lengths. Beamforming results from simulations and experiments show that in-band beamforming loses peak-to-sidelobe ratio and fails to reliably locate the source as the scatterer count increases. Using the same signals, frequency-difference beamforming with difference frequencies from 5 to 25 kHz localizes sources reliably with higher peak-to-side-lobe ratios, though with reduced resolution.
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization