Related Experiment Video
Updated: Jan 21, 2026

Creation of Patient-Specific Silicone Cardiac Models with Applications in Pre-surgical Plans and Hands-on Training
Published on: February 10, 2022
Optimization of surgical parameters based on patient-specific models: Application to arcuate keratotomy
Oskar Truffer1, Daniel Abler1, Bojan Pajic2
1Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland.
Purpose:
To determine surgical parameters for arcuate keratotomy by simulating the intervention with a patient-specific model.
Setting:
University Eye Clinic Salzburg, Paracelsus Medical University, Austria, and Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland.
Design:
Computational modeling study.
Methods:
A new approach to plan arcuate keratotomy based on personalized finite element simulations was developed. Using this numeric tool, an optimization algorithm was implemented to determine the incision parameters that best met the surgeon's requirements while preserving the orientation of the astigmatism. Virtual surgeries were performed on patients to compare the performance of the simulation-based approach with results based on the Lindstrom and Donnenfeld nomograms and with intrastromal interventions.
Results:
Retrospective data on 28 patients showed that personalized simulation reproduced the surgically induced change in astigmatism (Pearson correlation = 0.8). Patient-specific simulation was used to examine strategies for arcuate interventions on 621 corneal topographies. The Lindstrom nomogram resulted in low postoperative astigmatism (mean 0.03 diopter [D] ± 0.3 [SD]) but frequent overcorrections (20%). The Donnenfeld nomogram and intrastromal incisions resulted in a small amount of overcorrection (1.5%) but a wider spread in astigmatism (mean 0.63 ± 0.35 D and 0.48 ± 0.50 D, respectively). In contrast, the new numeric parameter optimization approach led to postoperative astigmatism values (mean 0.40 ± 0.08 D, 0.20 ± 0.08 D, and 0.04 ± 0.13 D) that closely matched the target astigmatism (0.40 D, 0.20 D, and 0.00 D), respectively, while keeping the number of overcorrections low (<1.5%).
Conclusion:
Using numeric modeling to optimize surgical parameters for arcuate keratotomy led to more reliable postoperative astigmatism, limiting the risk for overcorrection.
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Wave Parameters
Optimal Foraging
Optimization Problems
Distributions to Estimate Population Parameter