Related Experiment Video
Updated: Jan 21, 2026

Establishing a Diaphyseal Femur Fracture Model in Mice
Published on: December 9, 2022
Does fracture obliquity in Weber B fibula fractures correlate with mortise instability?
Brian T Velasco1, Christopher P Miller2, Michael Y Ye2
1Beth Israel Deaconess Medical Center, Boston, MA, United States; Geisinger Commonwealth School of Medicine, Scranton, MA, United States.
Background:
The diagnosis of instability in the apparent, isolated distal fibula fracture can be challenging and often necessitates stress radiography. Danis & Weber classified lateral malleolar fractures based on the level of the fracture in relation to the syndesmosis. While Weber B fractures occur at the level of the syndesmosis, some such injuries present with a long, oblique pattern extending well above the syndesmosis. Given the well-established literature demonstrating that fractures above the syndesmosis correlate with a higher level of concomitant syndesmotic and deltoid ligament injury, we hypothesize that increased fracture obliquity, length and height of Weber B fibula fractures similarly correlates with increased mortise instability.
Methods:
All patients with isolated Weber B fibula fractures who underwent gravity stress radiography met inclusion criteria. Fracture height was measured on mortise radiographs as: (1) the distance from the distal tip of the fibula to fracture apex, (2) the distance to the fracture apex as measured on a line drawn perpendicular to a line parallel to the plafond, (3) an angle subtended by a line drawn parallel to the plafond and a line drawn to the fracture apex and (4) a ratio of the absolute length as compared to fibular width.
Results:
51 patients were included in the study. The group of 39 patients with stable ankles had a mean medial clear space of 3.12 ± 0.65 mm (range, 1.5 mm to 4.0 mm). The group of 12 patients with unstable ankles had a mean medial clear space of 6.29 ± 3.11 mm (range, 4.1 mm to 14.0 mm). These groups showed no significant difference in fracture angle (p = 0.93), fracture height from plafond (p = 0.49), fracture height from tip of fibula (p = 0.42), and as a ratio of absolute length to fibular width (p = 0.85).
Conclusion:
Increased fracture obliquity, length and height of Weber B fibula fractures did not correlate with a higher incidence of mortise instability. Despite the lack of positive correlation, future studies should continue to investigate and identify radiographic parameters of distal fibula fractures that are most predictive of instability.
More Related Videos
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Microtubule Instability
Bones of the Lower Limb: Tibia and Fibula
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Stress on an Oblique Plane