Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Temporary ventricular assist device implantation by sternotomy-avoiding technique for bridge-to-decision therapy: a
Masatoshi Akiyama1, Konosuke Sasaki2, Satoshi Kawatsu2
1Division of Cardiovascular Surgery, Tohoku University Graduate School of Medicine, 1-1Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan. akiyamam@med.tohoku.ac.jp.
Objective:
Temporary ventricular assist device (VAD) is a commonly used therapeutic option for cardiogenic shock. Patients requiring this treatment are often critical, and clinical outcomes remain unsatisfactory. This study evaluated the feasibility and efficacy of a sternotomy-avoiding technique for temporary VAD implantation to improve patient outcomes.
Methods:
Between December 2012 and November 2018, seven patients underwent temporary VAD implantation by sternotomy-avoiding technique (SA group) and eight by median sternotomy technique (MS group). Pre- and intraoperative characteristics, postoperative 7-day hemodynamic parameters, 30-day mortality, and adverse events were compared between the groups.
Results:
More than 50% of the patients were mechanically supported before temporary VAD implantation. Cardiopulmonary bypass time was significantly shorter in the SA than in the MS group (84 min vs 215 min; p = 0.011); surgical time tended to be shorter in the SA group (385 min vs 461 min; p = 0.064). Pump index, cardiac index, mixed venous oxygen saturation, and central venous pressure did not differ significantly during the first seven days of support. The 30-day incidence of any adverse event was not significantly different between the groups. No patients in the SA group needed re-exploration for surgical bleeding. Thirty-day all-cause mortality rates were 29% in the SA group and 0% in the MS group (p = 0.11).
Conclusions:
The sternotomy-avoiding and conventional techniques resulted in comparable short-term hemodynamic support. The sternotomy-avoiding technique was associated with a potential reduction in risk of re-exploration for bleeding. These results support the usefulness of the sternotomy-avoiding procedure for selected patients.
Related Concept Videos
Frustration and Conflict: Avoidance-Avoidance, Double-Approach Avoidance
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Wheatstone Bridge
Thus, for accurate resistance measurements, a...
Cross-bridge Cycle
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...