Related Experiment Video
Updated: Jan 21, 2026

Demonstration of the Rat Ischemic Skin Wound Model
Published on: April 1, 2015
Comparison of wound strength, histologic, and aesthetic outcomes after microsurgical versus conventional skin closure
Katharine M Hinchcliff1, Timothy Orlowski2, Hakan Orbay1
1Division of Plastic Surgery, Davis Medical Center, University of California, Sacramento, CA, USA.
Abstract:
The purpose of this study was to compare the healing, strength, and cosmetic outcome of linear incisions after repair with the naked eye, surgical loupes, or a surgical microscope. Two parallel incisions were made on the dorsal skin of Sprague-Dawley rats (n = 36) and the rats randomized into four groups. A single surgeon repaired the incisions using 5-0 poliglecaprone in a running subcuticular pattern using the naked eye (Group I), surgical loupes with 2.5× magnification (Group II), surgical microscope with 5-10× magnification (Group III), and 6-0 poliglecaprone with a surgical microscope (Group IV). Rats were sacrificed at 1, 3, and 6 weeks. At each time point, the tensile strength of each closure was assessed. Macroscopic outcomes were evaluated using the Vancouver Scar Scale (VSS) and histology assessed by a blinded observer. Microscope closure took significantly longer than closure with the naked eye (p < 0.05). There was no significant difference in tensile strength or VSS ratings between the closure methods at any of the time points. On histopathologic analysis, there were a greater number of inflammatory cells and fibroblasts in the 6-0 microscope closure group versus the naked eye closure group at week 3 (p ≤ 0.05). In conclusion, wound repair under magnification did not yield a significant difference in cosmesis or wound tensile strength, but did increase operative time. Moreover, there was a trend toward increased inflammation with microscope-assisted closures, perhaps due to the increased suture burden.
Related Concept Videos
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Relation Between Tensile Strength and Compressive Strength of Concrete
Predicting Reaction Outcomes

