Performance of a web-based application measuring spot quality in dried blood spot sampling
Herman Veenhof1, Remco A Koster1,2, Randy Brinkman3
1Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Abstract:
Background The dried blood spot (DBS) method allows patients and researchers to collect blood on a sampling card using a skin-prick. An important issue in the application of DBSs is that samples for therapeutic drug monitoring are frequently rejected because of poor spot quality, leading to delayed monitoring or missing data. We describe the development and performance of a web-based application (app), accessible on smartphones, tablets or desktops, capable of assessing DBS quality at the time of sampling by means of analyzing a picture of the DBS. Methods The performance of the app was compared to the judgment of experienced laboratory technicians for samples obtained in a trained and untrained setting. A robustness- and user test were performed. Results In a trained setting the app yielded an adequate decision in 90.0% of the cases with 4.1% false negatives (insufficient quality DBSs incorrectly not rejected) and 5.9% false positives (sufficient quality DBSs incorrectly rejected). In an untrained setting this was 87.4% with 5.5% false negatives and 7.1% false positives. A patient user test resulted in a system usability score of 74 out of 100 with a median time of 1 min and 45 s to use the app. Robustness testing showed a repeatability of 84%. Using the app in a trained and untrained setting improves the amount of sufficient quality samples from 80% to 95.9% and 42.2% to 87.9%, respectively. Conclusions The app can be used in trained and untrained setting to decrease the amount of insufficient quality DBS samples.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Dry Friction
To illustrate this concept, imagine a wooden crate resting on a rough, non-uniform horizontal surface. When an external force is applied to...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Quality of Water