Related Experiment Video
Updated: Jan 21, 2026

Preparation and Using Phantom Lesions to Practice Fine Needle Aspiration Biopsies
Published on: September 29, 2009
Comparison between fine-needle biopsy and fine-needle aspiration for EUS-guided sampling of subepithelial lesions: a
Antonio Facciorusso1, Sumsum P Sunny2, Valentina Del Prete1
1Gastroenterology Unit, University of Foggia, Foggia, Italy.
Background And Aims:
There is limited evidence on the diagnostic performance of EUS-guided fine-needle biopsy (FNB) sampling in patients with subepithelial lesions. The aim of this meta-analysis was to compare EUS-guided FNB sampling performance with FNA in patients with GI subepithelial lesions.
Methods:
A computerized bibliographic search on the main databases was performed through May 2019. The primary endpoint was sample adequacy. Secondary outcomes were diagnostic accuracy, histologic core procurement rate, and mean number of needle passes. Summary estimates were expressed in terms of odds ratio (OR) and 95% confidence interval (CI).
Results:
Ten studies (including 6 randomized trials) with 669 patients were included. Pooled rates of adequate samples for FNB sampling were 94.9% (range, 92.3%-97.5%) and for FNA 80.6% (range, 71.4%-89.7%; OR, 2.54; 95% CI, 1.29-5.01; P = .007). When rapid on-site evaluation was available, no significant difference between the 2 techniques was observed. Optimal histologic core procurement rate was 89.7% (range, 84.5%-94.9%) with FNB sampling and 65% (range, 55.5%-74.6%) with FNA (OR, 3.27; 95% CI, 2.03-5.27; P < .0001). Diagnostic accuracy was significantly superior in patients undergoing FNB sampling (OR, 4.10; 95% CI, 2.48-6.79; P < .0001) with the need of a lower number of passes (mean difference, -.75; 95% CI, -1.20 to -.30; P = .001). Sensitivity analysis confirmed these findings in all subgroups tested. Very few adverse events were observed and did not impact on patient outcomes.
Conclusions:
Our results speak clearly in favor of FNB sampling, which was found to outperform FNA in all diagnostic outcomes evaluated.
Related Concept Videos
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Directing Effect of Substituents: meta-Directing Groups
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

