Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Integrating Mechanical and Biological Analysis in Tendinopathy Research
Published on: March 1, 2024
Ankle Dorsiflexion Strength Monitoring by Combining Sonomyography and Electromyography
Abstract:
Ankle dorsiflexion produced by Tibialis Anterior (TA) muscle contraction plays a significant role during human walking and standing balance. The weakened function or dysfunction of the TA muscle often impedes activities of daily living (ADL). Powered ankle exoskeleton is a prevalent technique to treat this pathology, and its intelligent and effective behaviors depend on human intention detection. A TA muscle contraction strength monitor is proposed to evaluate the weakness of the ankle dorsiflexion. The new method combines surface electromyography (sEMG) signals and sonomyography signals to estimate ankle torque during a voluntary isometric ankle dorsiflexion. Changes in the pennation angle (PA) are derived from the sonomyography signals. The results demonstrate strong correlations among the sonomyography-derived PA, the sEMG signal, and the measured TA muscle contraction force. Especially, the TA muscle strength monitor approximates the TA muscle strength measurement via a weighted summation of the sEMG signal and the PA signal. The new method shows an improved linear correlation with the muscle strength, compared to the correlations between the muscle strength and sole sEMG signal or sole PA signal, where the R-squared values are improved by 4.21 % and 1.99 %, respectively.
More Related Videos
Related Concept Videos
Ankle Joint
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Self-Presentation: Self-Monitoring and Self-Handicapping

