Related Experiment Video
Updated: Jan 21, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Comparison of Cardiac Output of Both 2-Dimensional and 3-Dimensional Transesophageal Echocardiography With
David Jeffrey Canty1, Martin Kim2, Ranjan Guha2
1Department of Surgery, (Royal Melbourne Hospital), University of Melbourne, Victoria, Australia; Department of Anaesthesia and Pain Management, The Royal Melbourne Hospital, Victoria, Australia; Department of Anaesthesia and Perioperative Medicine, Monash Medical Centre, Victoria, Australia.
Objectives:
To compare agreement and variability of cardiac output measurement of 2-dimensional (2D) and 3D transesophageal echocardiography (TEE) with thermodilution before and after bypass.
Design:
Prospective observational study.
Setting:
Two tertiary hospitals.
Interventions:
Cardiac output (CO) was measured simultaneously with thermodilution and TEE by multiplying either the left ventricular outflow tract area (LVOTA) or aortic valve area (AVA), the velocity-time integral (VTI) of flow at the same site, and heart rate. The LVOTA was calculated using diameter for 2D TEE. Planimetry was used for 3D TEE. The AVA was measured using planimetry.
Participants:
The study comprised 82 adult patients undergoing coronary or valve surgery.
Measurements And Main Results:
One hundred fifty-four complete sets of measurements were obtained (82 prebypass and 72 postbypass). All TEE methods had acceptable correlation and absence of proportional or fixed bias except for the left ventricular outflow tract (LVOT) VTI modal trace method, which had poor correlation and proportional but not fixed bias (regression coefficient [95% confidence interval], bias [percentage of mean CO]): 2D LVOT VTI modal trace 0.67 (0.54-0.80), -36.4%; 2D LVOT VTI outer edge trace 0.96 (0.80-1.12), -15.3%; 2D AVA planimetry 0.96 (0.75-1.18), +4.9%; 3D LVOT area planimetry 1.18 (0.96-1.41), +0.8%; 3D AVA planimetry 1.20 (0.93-1.46), +0.4%. All TEE methods had wide levels of agreement compared with thermodilution (-3.94 to +0.23 L/min, -2.83 to +1.28 L/min, -2.23 to +2.73 L/min, -2.35 to +2.42 L/min, and -2.57 to +2.61 L/min, respectively). Measurement variability was superior for all TEE methods compared with thermodilution before but not after bypass.
Conclusions:
Although limits of agreement of CO measurement with 3D TEE and thermodilution are wide, 2D planimetry of the AVA and continuous wave Doppler may be substituted for thermodilution before and after bypass.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Dimensional Analysis
Conversion Factors and Dimensional Analysis