Related Experiment Video
Updated: Jan 21, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Performance of deep learning for differentiating pancreatic diseases on contrast-enhanced magnetic resonance imaging:
1Shanghai Institute of Medical Imaging, 200032 Shanghai, China; Department of Interventional Radiology, Fudan University Zhongshan Hospital, 200032 Shanghai, China.
Purpose:
The purpose of this study was to evaluate the ability of deep learning to differentiate pancreatic diseases on contrast-enhanced magnetic resonance (MR) images with the aid of generative adversarial network (GAN).
Materials And Methods:
A total of 504 patients who underwent T1-weighted contrast-enhanced MR examinations before any treatments were included in this retrospective study. First, the MRI examinations of 398 patients (215 men, 183 women; mean age, 59.14±12.07 [SD] years [range: 16-85 years]) from one hospital were used as the training set. Then the MRI examinations of 50 (26 men, 24women; mean age, 58.58±13.64 [SD] years [range: 24-85 years]) and 56 (30 men, 26 women; mean age, 59.13±11.35 [SD] years [range: 26-80 years]) consecutive patients from two hospitals were separately collected as the internal and external validation sets. An InceptionV4 network was trained on the training set augmented by synthetic images from GANs. Classification performance of trained InceptionV4 network for every patch and every patient were made on both validation sets, respectively. The prediction agreement between convolutional neural network (CNN) and radiologist was measured by the Cohen's kappa coefficient.
Results:
The patch-level average accuracy and the micro-averaging area under receiver operating characteristic curve (AUC) of InceptionV4 network were 71.56% and 0.9204 (95% confidence interval [CI]: 0.9165-0.9308) for the internal validation set, and 79.46% and 0.9451 (95%CI: 0.9320-0.9523) for the external validation set, respectively. The patient-level average accuracy and the micro-averaging AUC of InceptionV4 network were 70.00% and 0.8250 (95%CI: 0.8147-0.8326) for the internal validation, 76.79% and 0.8646 (95%CI: 0.8489-0.8772) for the external validation set, respectively. Evaluated by human reader, the average accuracy and micro-averaging AUC for internal and external validation sets were 82.00% and 0.8950 (95%CI: 0.8817-0.9083), 83.93% and 0.9063 (95%CI: 0.8968-0.9212), respectively. The Cohen's kappa coefficients between InceptionV4 network and human reader for the internal and external invalidation sets were 0.8339 (95%CI: 0.6991-0.9447) and 0.8862 (95%CI: 0.7759-0.9738), respectively.
Conclusion:
Deep learning using CNN and GAN had the potential to differentiate pancreatic diseases on contrast-enhanced MR images.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Resonance