Case-Control Comparison of Conventional End-Hole versus Balloon-Occlusion Microcatheter Prostatic Artery Embolization
Raj Ayyagari1, Taylor Powell1, Lawrence Staib1
1Department of Radiology and Biomedical Imaging, Yale University School of Medicine, P.O. Box 208042, New Haven, CT 06520-8042.
Purpose:
To compare procedural metrics and clinical improvement for prostatic artery embolization (PAE) performed with a balloon-occlusion (BO) versus end-hole (EH) microcatheter in patients with benign prostatic hyperplasia.
Materials And Methods:
Retrospective review was performed of 129 patients undergoing PAE with 100-300 μm Embosphere microspheres from April 2013 through August 2018. Microcatheter selection was nonrandom, based on prostatic artery anatomy. Five technical failures and 5 microcatheter crossover cases were excluded. BO group (n = 46, age 72.8 y ± 9.0, gland volume 184 mL ± 83, 42% in retention) and EH group (n = 73, age 76.0 y ± 9.0, gland volume 190 mL ± 116, 44% in retention) were compared using procedural metrics (excluding 30 EH learning-curve cases); symptomatic improvement at 3, 6, and 12 months after PAE; voiding trial success; and adverse events (reported used Clavien-Dindo classification).
Results:
Procedural and fluoroscopy times were lower in the BO group (n = 46) vs EH group (n = 43) (152.0 min ± 34.0 vs 172.8 min ± 47.9, P < .02; 37.8 min ± 12.9 vs 50.3 min ± 18.9, P < .001). Collaterals coiled, contrast material used, and injected particle volume were similar for both groups (P = NS). International Prostate Symptom Score improvement was similar for BO group (n = 25) (before PAE 23.5 ± 6.5, 12 months after PAE 7.6 ± 6.8) and EH group (n = 30) (before PAE 20.9 ± 5.9, 12 months after PAE 6.6 ± 5.2) (P = NS). Quality-of-life improvements were also similar (BO: before PAE 4.5 ± 1.2, 12 months after PAE 1.4 ± 0.9; EH: before PAE 4.1 ± 1.0, 12 months after PAE 0.9 ± 0.7), as were 12-month postvoid residual improvements, voiding trial failure rates (EH 12%, BO 8%), and adverse event rates (grade II, III: EH 15%, BO 11%) (P = NS for all).
Conclusions:
BO microcatheter use in PAE did not affect injected particle volume, contrast material use, or protective coiling and did not impact symptomatic improvement, postvoid residual improvement, voiding trial success, or adverse events after PAE. Lower procedure and fluoroscopy times with BO microcatheter were likely due to selection bias.
More Related Videos
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Phosphodiesterase Inhibitors
Among the PDE5 inhibitors, sildenafil (Revatio) stands out as a competitive and selective inhibitor. It operates by elevating cellular levels of cGMP and augmenting signaling through the cGMP-PKG pathway, promoting vasodilation. Upon oral...
Pulmonary Embolism I: Introduction
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...