Background:
The aim of this study was to evaluate the influence of two harvesting approaches on the donor site vascular injury.
Methods:
A split-mouth cadaver study was designed on 21 fresh donor heads. Every hemi-palate was assigned to receive the trap-door harvesting technique (TDT) or the epithelialized free gingival graft harvesting technique (FGGT). A soft tissue graft was harvested from each side for histology analyses. Betadine solution was used to inject the external carotid artery and a collagen sponge was positioned over the harvested area to compare the amount of "leakage."
Results:
The mean leakage observed was 16.56 ± 3.01 µL in the FGGT-harvested sites, and 69.21 ± 7.08 µL for the TDT group, a ratio of 4.18 (P < 0.01). Regression analyses demonstrated a trend for more leakage at thinner palatal sites for the FGGT group (P = 0.09), and a statistically significant correlation for the TDT-harvest sites (P = 0.02). Additionally, a shallow palatal vault height (PVH) was associated with a higher leakage in both harvesting groups (P = 0.02). The histomorphometric analyses revealed that grafts harvested with TDT exhibited a significantly higher mean number of medium (ø = 0.1 to 0.5 mm, P = 0.03), and large vessels (ø ≥ 0.5 mm, P = 0.02).
Conclusions:
Within the limitations of the present research, the TDT resulted in a significantly higher leakage than the FGGT, which was also correlated with the histology analyses where a greater number of medium and large vessels were observed in the harvested grafts.
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Imaging Studies VII: Vascular Imaging
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Seedless Vascular Plants
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Bioavailability: Influencing Factors