Percutaneous Continuous Irrigation and Drainage for Infected Obturator Bypass Graft

Mamoru Hamuro1, Shuji Setozaki1, Kenji Yamamoto1

  • 1Department of Cardiovascular Surgery, Okamura Memorial Hospital, Shizuoka, Japan.

Related Concept Videos

Design Example: Design of an Irrigation Channel01:27

Design Example: Design of an Irrigation Channel

Trapezoidal channels are widely used in irrigation systems due to their cost-effectiveness and efficiency in conveying water. Trapezoidal channels feature a flat bottom and sloping sides, making them stable and easier to construct compared to other shapes. The bottom width and side slope ratio are determined based on the required flow capacity and site conditions. The side slope is kept gentle for unlined channels to prevent soil erosion.Hydraulic parameters in channel design include the flow...
782
Cavity Drainage and Flashings in Masonry walls01:20

Cavity Drainage and Flashings in Masonry walls

Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
428
Continuing Care01:25

Continuing Care

Continuing care describes the variety of health, personal, and social services provided over a prolonged period. The need for continuing care is increasing because people are living longer. Many people do not have families or others to care for them. Continuing care is mainly for patients who are disabled, functionally dependent, or suffering from a terminal disease. It is available within institutional settings or in homes. Examples include nursing centers or facilities, assisted living,...
1.9K
Continuity Equation01:28

Continuity Equation

The continuity equation asserts that the mass flow rate must remain constant for a steady flow of an incompressible fluid within a confined system. This principle applies to systems where fluid passes through varying cross-sectional areas, such as nozzles, syringes, and pipes.
The mass flow rate is expressed as:
3.3K
Continuity Equation01:20

Continuity Equation

The total amount of current flowing per unit cross-sectional area is called the current density. Hence, the current passing through a cross-sectional area can be written as the surface integral of the current density.
1.5K
Equation of Continuity01:12

Equation of Continuity

Fluid motion is represented by either velocity vectors or streamlines. The volume of a fluid flowing past a given location through an area during a period of time is called the flow rate Q, or more precisely, the volume flow rate. Flow rate and velocity are related—for instance, a river has a greater flow rate if the velocity of the water in it is greater. However, the flow rate also depends on the size and shape of the river. The relationship between flow rate (Q) and average speed (v)...
10.5K