Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Ratiometric electrochemical biosensor based on Exo III-Assisted recycling amplification for the detection of CAG
Yalan Liu1, Zhiqi Ge1, Meijun Chen1
1Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Youyi Road 368, Wuchang, Wuhan, Hubei, 430062, PR China.
Abstract:
Electrochemical detection of specific nucleic acid sequence remains a hot topic in current bioanalytical research. Here, a novel ratiometric electrochemical biosensor based on Exo III-assisted recycling amplification and graphene-modified electrode was fabricated for quantitative detection of trinucleotide repeat sequence d(CAG)n. The double-signals used are the hairpin DNAs labeled with ferrocene and methylene blue respectively as report DNAs, which can hybridize to target DNA. The hybridized DNA was digested by Exo III, resulting in the release of target and report fragments. The graphene-modified electrode can selectively adsorb the released report fragments to generate double electrochemical signals. The signal ratio (F/M) of ferrocene and methylene blue was used to determine the repeat length accurately: a linear relationship was found between F/M and numbers of repeats (n), F/M = 0.061 n + 1.97, with a correlation coefficient of 0.992. Moreover, any electrochemical signal can be used to test repeat concentration with detection limit of 0.22 pM. Therefore, this novel ratiometric electrochemical biosensor provided a reliable and efficient method for the analysis of d(CAG)n trinucleotide repeat and a potential simplified clinical tool for neurodegenerative diseases.
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Recycling Endosomes and Transcytosis
The recycling endosome is not a single organelle but an extensively tubulated network of recycling pathways. It functions in storing molecules or transporting them across...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
RACE - Rapid Amplification of cDNA Ends
Interfacial Electrochemical Methods: Overview
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...