Related Experiment Video
Updated: Jan 21, 2026

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
Electrochemical immunosensor based on gold-labeled monoclonal anti-LipL32 for leptospirosis diagnosis
Sakda Jampasa1, Prayoon Lae-Ngee2, Kanitha Patarakul2
1Metallurgy and Materials Science Research Institute, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand.
Abstract:
Leptospirosis is a critical human health problem in the tropical area, thus, a precise technique that can be used for point-of-care analysis is greatly required. This is the first report on electrochemical immunosensor based on gold-labeled monoclonal anti-LipL32 for rapid, simple and sensitive determination of LipL32. The sensor consisted of two LipL32-specific antibodies: an unlabeled capture primary antibody (Anti-1°Ab) and an electrochemically detectable gold-conjugated secondary antibody (Au-2°Ab). The Anti-1°Ab was immobilized onto the modified screen-printed graphene electrode (SPGE) to form the anti-LipL32 surface. The electrochemical signal response was determined by differential pulse voltammetry (DPV). In the presence of LipL32, the sensor displayed a significant increase in current response in a concentration-dependent manner, but no observable signal was detected in the absence of LipL32. The linearity between LipL32 concentration and the measured current was found in a range of 1-100 ng/mL, and the limit of detection (LOD) (3SDblank/Slope) and limit of quantitation (LOQ) (10SDblank/Slope) were found to be 0.28 and 0.93 ng/mL, respectively. This sensor was successfully applied to detect pathogenic Leptospira whole cell lysates samples with the satisfactory results. The promissing results suggested that this immunosensor might be an alternative tool for diagnosis of leptospirosis.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Interfacial Electrochemical Methods: Overview
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Diabetes: Symptoms, Diagnosis, and Complications

