Retrospective comparison of equine hemoglobin oxygen saturation measured by a human-specific co-oximeter, or derived
1Department of Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada.
Objective:
Hemoglobin oxygen saturation (SO2) is measured by co-oximetry (SO2cox) or calculated from partial pressure of oxygen (PO2) using algorithms (SO2alg). To compare venous and systemic arterial blood sample data retrospectively and to examine whether temperature correction of PO2 is important.
Study Design:
Retrospective study.
Animals:
A group of 21 healthy, adult, sedated or anesthetized horses.
Methods:
Mixed-venous and systemic arterial blood samples (1 mL) were anaerobically collected using commercial preheparinized syringes from the right ventricle and facial artery, respectively. Blood was analyzed using a commercial gas analyzer and human-specific co-oximeter within 10 minutes of collection or stored on ice and analyzed within 30 minutes. PO2 was measured at 37 °C and corrected using body temperature (Tcore) from a pulmonary artery catheter thermistor. SO2cox and hemoglobin subtypes were measured by co-oximetry (37 °C). An algorithm developed for Thoroughbred horse blood was used to calculate SO2alg using PO2 at 37 °C and SO2algcorr with PO2 corrected to Tcore. SO2alg and SO2algcorr were each paired with SO2cox using Bland-Altman (repeated measures) ratio of SO2alg/SO2cox (204 samples).
Results:
SO2alg overestimated SO2cox when PO2 was <80 mmHg (10.7 kPa); ratio and limits of agreement: 1.2 (0.9-1.6) but became accurate when PO2 was ≥80 mmHg: 1.0 (1.0-1.0). With all data, SO2algcorr did not differ from SO2alg:1.1 (0.8-1.4). Methemoglobin (FMetHb) and carboxyhemoglobin (FCOHb) were significantly higher in venous [FMetHb: median (range): 1.8 (0-2.9)%; FCOHb: 0.1 (0-2)%] than in arterial blood [FMetHb: 0.5 (0-2.2)%; FCOHb: 0 (0-0.3)%].
Conclusions:
The algorithm appeared robust when PO2 was ≥80 mmHg (10.7 kPa) but overestimated when PO2 was lower. Temperature correction was not important within 34.9-37.3 °C.
Clinical Relevance:
SO2alg overestimation in venous blood can result in calculation of higher intrapulmonary shunt fraction than SO2cox values.
More Related Videos
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
09:47Author Spotlight: Utilizing Next-Generation Polymerized Human Hemoglobin for Improved Donor Lung Evaluation and Preservation in Rats
Published on: June 14, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Oxygenic Photosynthesis
Oxygen Requirements and Growth Patterns
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: