Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Intraobserver and interobserver reliability of cone beam weightbearing semi-automatic three-dimensional measurements
Alessio Bernasconi1, Lucy Cooper2, Shirley Lyle2
1Foot and Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, United Kingdom; Department of Public Health, Trauma and Orthopaedics, University of Naples Federico II, Naples, Italy.
Introduction:
Pes cavovarus is a three-dimensional (3D) foot deformity. New 3D semi-automatic measurements utilising weightbearing computerised topography (WBCT) images have recently been proposed to assess hindfoot alignment, but reliability in pes cavovarus has never been investigated. The aim of this study was to assess intraobserver and interobserver reliability of the foot ankle offset (FAO), calcaneal offset (CO) and hindfoot alignment angle (HAA) in pes cavovarus.
Methods:
Anonymised WBCT datasets from 51 feet (17 Charcot-Marie-Tooth related cavovarus, 17 idiopathic cavovarus and 17 controls) were retrospectively reviewed. Three observers (two senior foot and ankle fellows and one orthopaedic resident) independently measured FAO, CO and HAA using dedicated software, with measurements repeated two weeks apart. Subgroup analysis was performed to assess whether aetiology or severity of varus deformity and level of seniority affected reliability.
Results:
Mean values for intra and interobserver reliability for FAO (r=0.98; ICC: 0.99), CO (r=0.97; ICC: 0.98) and HAA measurements (r=0.97; ICC: 0.98) were excellent. Subgroup analyses showed that FAO, CO and HAA's intra (r/ρ range, 0.77-0.95) and interobserver (ICC range, 0.88-0.98) reliability remained excellent in patients with Charcot-Marie-Tooth related cavovarus, idiopathic pes cavovarus and normal feet, regardless of the severity of deformity. No difference was found in FAO, CO and HAA mean values from three observers (p>0.05 in all cases).
Discussion:
This study demonstrates that 3D semi-automatic measurements of WBCT images have excellent intra and interobserver reliability in the assessment of hindfoot alignment in pes cavovarus. Aetiology and severity of deformity, and level of seniority do not affect reliability of these measurements.
Level Of Evidence:
Level III, retrospective comparative study.
More Related Videos
Related Concept Videos
Reliability and Validity
Automatic Processing and Automatic Social Behavior
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Distribution Reliability and Automation
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...

