Bagolini filter bars: an analysis of light transmittance and their use in a pediatric population
Laura C England1, Helen Davis2
1a Orthoptic Department, Manchester Royal Eye Hospital , Manchester.
Insights
The Sbisa bar and Bagolini Filter bar show inconsistencies in measuring suppression or abnormal binocular vision in children. Further research is needed for reliable filter bars in pediatric eye exams.
Area of Science:
- Ophthalmology
- Pediatric Optometry
- Vision Science
Background:
- Accurate measurement of suppression and abnormal binocular single vision (BSV) is crucial for pediatric eye care.
- Filter bars are commonly used tools, but their reliability and comparability across different types and manufacturers require investigation.
Purpose of the Study:
- To assess the repeatability and comparability of the Sbisa bar (BF(Sbisa)) and Bagolini Filter bar (BF(new)) for measuring suppression density and abnormal BSV strength in children.
- To evaluate the consistency of light transmittance across filter numbers for both bar types.
Main Methods:
- Light transmittance of filters on BF(Sbisa) and BF(new) bars was measured using a spot photometer.
- Thirty-three children (5-12 years) with unilateral strabismus participated.
- Suppression density/abnormal BSV strength was measured twice with each bar type, including repeated measures.
Main Results:
- Light transmittance did not consistently decrease with increasing filter numbers.
- BF(Sbisa) bars were not comparable to BF(new) bars when using filter numbers or light transmittance values.
- Both BF(Sbisa) and BF(new) bars demonstrated poor repeatability, and an order effect was observed in measurements.
Conclusions:
- Current BF(Sbisa) and BF(new) bars exhibit significant inconsistencies, limiting their reliability for measuring suppression or abnormal BSV in pediatric populations.
- There is a need for filter bars with consistent and comparable light transmittance properties.
- Using only BF(new) bars is preferable to BF(Sbisa) or mixed use, and repeated measurements within 2 minutes are not recommended due to potential order effects.
Abstract:
Purpose: The purpose of this study is to determine whether the Sbisa bar (Sbisa Ophthalmic Instruments) (referred to in this article as the BF(Sbisa) bar) and Bagolini Filter bar (C.O.I. Vision) (referred to in this article as the BF(new) bar) are repeatable and comparable, for measuring density of suppression or strength of abnormal binocular single vision (BSV), in a pediatric population. Methods: Using a spot photometer, percentage light transmittance of filters on two BF(Sbisa) bars and two BF(new) bars was measured. Thirty-three participants aged 5-12 years with unilateral strabismus were recruited. Density of suppression or strength of abnormal BSV was measured with two of each bar, in addition to a repeated measure with one of each bar. Results: Light transmittance did not reduce consistently with increasing filter number (the number assigned to each filter by the manufacturer). Using data as filter numbers, a BF(Sbisa) bar was not comparable to a BF(new) bar (ᵶ = -3.936, p < 0.001, r = -0.28); different BF(Sbisa) bars were not comparable (ᵶ = -3.103, p = 0.005, r = -0.22) but different BF(new) bars were comparable (ᵶ = -1.165, p = 1.285, r = -0.08). Using light transmittance values, a BF(Sbisa) bar was comparable to a BF(new) bar (ᵶ = -0.385, p = 3.535, r = -0.03); different BF(Sbisa) bars were comparable (ᵶ = -1.476, p = 0.720, r = -0.10) but different BF(new) bars were not comparable (ᵶ = -3.354, p < 0.001, r = -0.24). The BF(Sbisa) and BF(new) bars were not repeatable using filter numbers (ᵶ = -3.648, p < 0.001, r = -0.26 and ᵶ = -3.099, p = 0.005, r = -0.22, respectively) or light transmittance values (ᵶ = -3.743, p < 0.001, r = -0.27 and ᵶ = -2.727, p = 0.025, r = -0.19, respectively). An order effect existed using filter numbers (ᵶ = -4.473, p < 0.001, r = -0.32) and light transmittance values (ᵶ = -4.525, p < 0.001, r = -0.32). Conclusion: There is a need for the production of bars with consistently reducing and comparable light transmittance of filters if measurement of density of suppression or strength of abnormal BSV with filter bars is to continue, because the current bars show inconsistencies, particularly at lower filter numbers. In the meantime, the bars are limited by their lack of comparability or repeatability. Using only BF(new) bars is preferable to using BF(Sbisa) bars or a mixture of the two types of bar because two different BF(new) bars may be comparable using filter number readings, but filter number readings from different BF(Sbisa) bars or from a BF(Sbisa) and BF(new) bar are not comparable. As the BF(Sbisa) and BF(new) bars are currently labeled, a second measure of density of suppression or strength of abnormal BSV is not recommended within 2 min of an initial measurement, because the measurement procedure seems to cause a reduction in suppression or abnormal BSV that does not recover with repeated measurements 2 min apart.
More Related Videos
Related Concept Videos
Bar Graph
Multiple Bar Graph
Each bar or column in the multiple bar graph represents a data value. These graphs are used primarily in interrelating two or more sets of data. The categories of different kinds of data are listed along the horizontal or x-axis, whereas...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Analysis of Population Pharmacokinetic Data
Active Filters
Conservation of Small Populations