Investigation of Low-Current Direct Stimulation for Rehabilitation Treatment Related to Muscle Function Loss Using

Jiahui Wang1,2,3, Hao Wang1,3, Tianyiyi He1,3,4

  • 1Department of Electrical and Computer Engineering National University of Singapore 4 Engineering Drive 3 117576 Singapore.

Related Concept Videos

Muscle Stimulation Frequency01:22

Muscle Stimulation Frequency

The contraction strength of muscles is regulated by motor neurons, which modulate the frequency of action potentials dispatched to the motor units based on the body's requirements. This process of varying the muscle stimulation frequency allows muscles to contract with a force that is precisely tailored to the needs of the moment, whether lifting a feather or a heavy box.
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
4.3K
Loss of Tumor Suppressor Gene Functions01:12

Loss of Tumor Suppressor Gene Functions

Tumor suppressor genes are normal genes that can slow down cell division, repair DNA mistakes, or program the cells for apoptosis in case of irreparable damage. Hence, they play an essential role in preventing the proliferation of damaged cells.
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
5.9K
Functions of Smooth Muscles01:23

Functions of Smooth Muscles

Smooth muscles are an important type of muscle tissue that plays a vital role in the involuntary movements of internal organs. For example, they help regulate the movement of food through the gut and the flow of blood through the circulatory system.
Function of visceral smooth muscles
Visceral smooth muscle is found in the walls of all hollow organs, except the heart, and is a key player in the involuntary movements that drive the functioning of these internal organs. This tissue is arranged in...
3.2K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
517
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
370
Power01:08

Power

The concept of work involves force and displacement; meanwhile, the work-energy theorem relates the net work done on a body to the difference in its kinetic energy, calculated between two points on its trajectory. While none of these quantities or relations involves time explicitly, we know that the time available to accomplish work is often just as important as the amount of work itself. For example, sprinters in a race may have achieved the same velocity at the finish, therefore,...
12.9K