Related Experiment Video
Updated: Jan 21, 2026

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays
Published on: October 4, 2019
A Method of Flexible Micro-Wire Electrode Insertion in Rodent for Chronic Neural Recording and a Device for Electrode
Abstract:
Reliable chronic neural recording from focal deep brain structures is impeded by insertion injury and foreign body response, the magnitude of which is correlated with the mechanical mismatch between the electrode and tissue. Thin and flexible electrodes cause less glial scarring and record longer than stiff electrodes. However, the insertion of flexible microelectrodes in brain has been a challenge. Here, a novel insertion method is proposed, and demonstrated, for precise targeting deep brain structures using flexible micro-wire electrodes. The microelectrode is spun and slowly inserted in brain through an appropriate electrode guide. The electrode guide does not penetrate into cortex. Based on two new mechanisms, namely spinning and guided insertion, we have demonstrated successful insertion of 25-micron platinum flexible electrodes about 10-mm deep in rat brains without buckling. We present an electrode insertion device based on the proposed method and demonstrate its use to implant flexible microelectrodes in rat brains. The step-by-step insertion process is described. Microelectrodes were inserted in the Bötzinger complex and respiratory neural activity was recorded acutely in nine rats and chronically in two rats for 50 days.
More Related Videos
Related Concept Videos
Standard Electrode Potentials
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...

