Related Experiment Video
Updated: Jan 21, 2026

Stereotaxic Surgery for Implantation of Microelectrode Arrays in the Common Marmoset Callithrix jacchus
Published on: September 29, 2019
Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery
Karim El Kholy1,2, Rafael Lazarin1, Simone F M Janner1
1Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Objective:
To investigate the effect of surgical guide support and implant site location on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous patients.
Materials And Methods:
375 replica implants were inserted in 85 study models. Surgical implant placement was done using static 3D printed surgical guides, which were designed to be supported either by all the teeth present in the model (full arch), or by 4-teeth), 3-teeth or 2-teeth. Each study model included three single-tooth gap (STG) situations; one extraction socket site and two implants placed in a distal extension situation. Preplanned and postoperative implant positions were compared using the treatment-evaluation tool in digital software. 3-dimensional and angular deviations were measured. Statistical analysis was done using ANOVA, and pairwise t tests and Bonferroni-Holm's adjustment were applied as a post hoc test.
Results:
Accuracy of surgical guides used in sCAIS was significantly affected by the number and type of teeth used for its support. Guides supported by 4 teeth were not significantly different from accuracy of full-arch-supported guides (p > .05). Guide support by posterior teeth was associated with an increased level of accuracy, when compared to anterior teeth guide support. Implants placed in extraction sockets were associated with significantly higher 3D and angular deviation values (p < .05), and surgical guides with a distal extension situation resulted in significantly higher deviation values (p < .05).
Conclusion:
The number and location of teeth supporting the surgical guide can significantly influence the accuracy of sCAIS, with 4 teeth providing equal accuracy to full-arch guides in (STG) situations.
Related Concept Videos
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Static Equilibrium - I
Static Equilibrium - II
Static Friction
For example, consider a scenario where a truck is connected to a car by a rope, ready to tow it along a road. When no external force is applied by the truck, the car remains stationary and is said to be in static equilibrium. In this case, the forces acting on the car, such as gravity and the...
Accuracy and Precision

