Validity of temperature, duration, and vessel seal on 24-hour urinary hydration markers
William M Adams1, J D Adams2, Eleni M Karras1
1Department of Kinesiology, University of North Carolina at Greensboro, Greensboro, NC, United States of America.
Abstract:
The purpose of this study was to examine the effect of storage temperature, duration, and storage vessel seal on 24 h urinary hydration markers. Twenty-one males (n = 8) and females (n = 13) (mean±SD; age, 24±5 y; body mass, 68.9±24.2 kg; height, 160.2±32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers were enrolled in this study. Participants provided a 24 h urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7°C and 22°C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed) or the manufacturers cap plus laboratory wrapping film (double sealed). Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG) and urine color (UCOL). UOSMO was stable at 7°C for two days (mean difference [95% CI]; +1 mmol·kg-1 [0+3], p>0.05) and three days (+1 mmol·kg-1 [0, +3], p>0.05) for single sealed and double sealed containers, respectively. USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22°C. UCOL measures were maintained for up to three days in all storage methods (p>0.05). In conclusion, if immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24 h urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 h.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Hydration of Cement
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Reliability and Validity
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Introduction to Urinary System
The kidneys are bean-shaped organs located in the retroperitoneal space, on either side of the vertebral column, between the T12 and L3 vertebrae. They are partially protected by the rib cage and surrounded by perirenal fat, which provides cushioning. They are responsible for urine formation and play critical roles in regulating blood pressure, electrolyte levels, and hormone production. The ureters...