Fast fluorometric enumeration of E. coli using passive chip
Related Experiment Video
Updated: Jan 21, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Esin Nagihan Kasap1, Üzeyir Doğan1, Ferah Çoğun2
1Gazi University, Faculty of Pharmacy, Department of Analytical Chemistry, 06330, Etiler, Ankara, Turkey.
Abstract:
In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 101-105 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
Fast Fourier Transform
The computational efficiency of the FFT becomes...
Chemotaxis in E. coli
Stringent Response in E. coli

