Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology
Hong Luo1, Deye Yang1, Andrew Barszczyk2
1The Affiliated Hospital of Hangzhou Normal University (H.L., D.Y., J.W.), Hangzhou Normal University, Zhejiang, China.
Background:
Cuff-based blood pressure measurement lacks comfort and convenience. Here, we examined whether blood pressure can be determined in a contactless manner using a novel smartphone-based technology called transdermal optical imaging. This technology processes imperceptible facial blood flow changes from videos captured with a smartphone camera and uses advanced machine learning to determine blood pressure from the captured signal.
Methods:
We enrolled 1328 normotensive adults in our study. We used an advanced machine learning algorithm to create computational models that predict reference systolic, diastolic, and pulse pressure from facial blood flow data. We used 70% of our data set to train these models and 15% of our data set to test them. The remaining 15% of the sample was used to validate model performance.
Results:
We found that our models predicted blood pressure with a measurement bias±SD of 0.39±7.30 mm Hg for systolic pressure, -0.20±6.00 mm Hg for diastolic pressure, and 0.52±6.42 mm Hg for pulse pressure, respectively.
Conclusions:
Our results in normotensive adults fall within 5±8 mm Hg of reference measurements. Future work will determine whether these models meet the clinically accepted accuracy threshold of 5±8 mm Hg when tested on a full range of blood pressures according to international accuracy standards.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer