Related Experiment Video
Updated: Jan 21, 2026

Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Foveal avascular zone and macular vessel density after correction for magnification error in unilateral amblyopia
Syunsuke Araki1,2, Atsushi Miki3,4, Katsutoshi Goto1
1Department of Ophthalmology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan.
Background:
To investigate the area of foveal avascular zone (FAZ) and macular vessel density (VD) after correction for magnification error in unilateral amblyopia using optical coherence tomography angiography (OCTA).
Methods:
Participants comprised 15 patients with unilateral amblyopia due to anisometropia with or without strabismus (mean age, 9.8 ± 3.4 years; range, 6-17 years). OCTA images were obtained by using spectral-domain OCT with angiography software. The OCTA scanning protocol used was 3 × 3-mm volume scan centered on the fovea. OCTA images were corrected for magnification errors using individual axial length (AL), and an adjusted 2.3 × 2.3-mm square was derived as a region of interest. The FAZ area and VD in both superficial capillary plexus (SCP) and deep capillary plexus (DCP) layers, foveal minimum thickness (FMT) were assessed using built-in OCTA software and ImageJ software (NIH, Bethesda, MD).
Results:
LogMAR in the amblyopic eyes was significantly poorer than that of the fellow eye (p < 0.001). AL was significantly shorter in the amblyopic eye than in the fellow eye (p < 0.001). FAZ area of SCP in amblyopic eyes was significantly smaller than that of fellow eyes (p < 0.001). No significant differences were seen in FAZ area of DCP, VD of SCP, VD of DCP, and FMT between amblyopic and fellow eyes (p = 0.07, 0.43, 0.55, and 0.25, respectively).
Conclusions:
Our present study after magnification error correction found smaller FAZ area of SCP in the amblyopic eye compared with the fellow eyes, but there was no significant difference in the macular VD between the amblyopic and fellow eyes.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Hybrid Zones
Distance Corrections
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...

