Related Experiment Video
Updated: Jan 21, 2026

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
Published on: April 14, 2023
Sterility and Stability of Diluted Meloxicam in Compounded Multi-dose Vial after 365 Days
Hironori K Kawano1, Gregory D Simonek2, Andrea D Moffitt1
1School of Veterinary Medicine, University of California, Davis, California.
Abstract:
Meloxicam is a common analgesic for rodents. Because meloxicam is only formulated commercially for companion animals, it requires dilution to achieve doses appropriate for small, laboratory species. Compounded multidose vial (cMDV) are often created to dilute and store a diluted drug. However, chronic cMDV use runs the risk of contamination and becoming a potential source of nosocomial infection. In this study, we created 15 cMDV by diluting meloxicam with sterile water (dilution, 1:10). cMDV were punctured once daily for 30 d. To determine the sterility of the diluted meloxicam, we assessed 8 cMDV for bacterial growth on days 0, 10, 20, 30, and 365 and tested them for endotoxin on days 0, 30, and 365. In addition, the stability of the remaining 7 cMDV was assessed on days 0, 10, 20, 30, and 365, by using liquid chromatography-diode assays. No bacterial growth or endotoxin was detected at any time point, and the drug concentrations remained stable over 365 d. Given the results this study, we believe that cMDV of diluted meloxicam can remain sterile and stable for 365 d.
More Related Videos
08:28Assessment of the Effects of Endocrine Disrupting Compounds on the Development of Vertebrate Neural Network Function Using Multi-electrode Arrays
Published on: April 26, 2018
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Solution Concentration and Dilution
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...