Related Experiment Video
Updated: Jan 21, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Circumferential and radial deformation assessment in premature infants: Ready for primetime?
Neidin Bussmann1, Aisling Smith1, Alessia Cappelleri1
1Department of Neonatology, The Rotunda Hospital, Dublin, Ireland.
Background:
Speckle tracking echocardiography (STE) is a validated method to measure longitudinal deformation in premature infants, but there is a paucity of data on STE-derived circumferential and radial strain in this population. We assessed the feasibility and reproducibility of circumferential and radial deformation measurements in premature infants.
Methods:
In a prospective study of 40 premature infants (<29 weeks of gestation at birth), STE-derived circumferential and radial strain, systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) were measured on day 2 and day 8. Intra- and inter-observer reproducibility analysis were performed using Bland-Altman analysis, coefficient of variation (COV), and intra-class correlation coefficient (ICC). The impact of a persistent patent ductus arteriosus (PDA) was analyzed.
Results:
Deformation analysis was feasible in 98% of the acquisitions. Circumferential parameters demonstrated excellent intra- and inter-observer reproducibility with an ICC between 0.89 and 0.99 (all P < 0.001) and a COV between 4% and 13%. Radial parameters demonstrated acceptable intra- and inter-observer reproducibility with an ICC between 0.73 and 0.96 (all P < 0.001) and a COV between 14% and 27%. Infants with a PDA on day 8 (n = 21, 53%) demonstrated higher radial strain, SRs and SRe. There were no differences in circumferential parameters with a PDA at either time point.
Conclusion:
This study demonstrates clinical feasibility and reproducibility of circumferential and radial strain by STE in premature infants. A PDA elevates radial deformation measures, suggesting that the increased LV preload from a PDA may augment intrinsic contractility in the radial but not circumferential plane.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Ready Mixed Concrete
Plastic Deformations
Plastic Deformations
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...

