Related Experiment Video
Updated: Jan 21, 2026

Nanoparticle Tracking Analysis of Gold Nanoparticles in Aqueous Media through an Inter-Laboratory Comparison
Published on: October 20, 2020
Comparative analysis of calculating sigma metrics by a trueness verification proficiency testing-based approach and
Runqing Li1, Tengjiao Wang1, Lijun Gong1
1Department of Laboratory Medicine, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China.
Introduction:
Two methods were compared for evaluating the sigma metrics of clinical biochemistry tests using two different allowable total error (TEa) specifications.
Materials And Methods:
The imprecision (CV%) and bias (bias%) of 19 clinical biochemistry analytes were calculated using a trueness verification proficiency testing (TPT)-based approach and an internal quality control data inter-laboratory comparison (IQC)-based approach, respectively. Two sources of total allowable error (TEa), the Clinical Laboratory Improvement Amendments of 1988 (CLIA '88) and the People's Republic of China Health Industry Standard (WS/T 403-2012), were used to calculate the sigma metrics (σCLIA, σWS/T ). Sigma metrics were calculated to provide a single value for assessing the quality of each test based on a single concentration level.
Results:
For both approaches, σCLIA > σWS/T in 18 out of 19 assays. For the TPT-based approach, 16 assays showed σCLIA > 3, and 12 assays showed σWS/T > 3. For the IQC-based approach, 19 and 16 assays showed σCLIA > 3 and σWS/T > 3, respectively.
Conclusions:
Both methods can be used as references for calculating sigma metrics and designing QC schedules in clinical laboratories. Sigma metrics should be evaluated comprehensively by different approaches.
Related Concept Videos
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Chemical Equilibria: Systematic Approach to Equilibrium Calculations
The first step is to identify all the chemical reactions involved, The...
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:

