Related Experiment Video
Updated: Jan 21, 2026

Isolation of Human Umbilical Vein Endothelial Cells HUVEC
Published on: April 28, 2007
Variation of the maximum velocity along the umbilical vein supports the Reynolds pulsometer model
X Capelle1, J P Schaaps1, J V Bavi Dido1
1CHU of Liege, Department of Obstetrics and Gynaecology, 4000, Liege, Belgium.
Objective:
To challenge, with a modern sonographic approach and a numerical model, the Reynolds's concept which suggests that the vascular structure of the umbilical cord could act as a pulsometer facilitating the venous return to the foetus.
Method:
Forty-five patients between 20 and 28 weeks of gestation were included in the study. The blood maximum velocity in the umbilical vein, measured at both foetal and placental ends, was assessed. Several sonographic parameters of the cord, including the diameter of the umbilical vein at both extremities, cord cross-sectional area and Wharton's jelly section surface were measured. We compare our data with those of a numerical model.
Results:
A difference in maximum velocity between the two extremities of the umbilical vein (ΔUVVmax) was noted. The maximum velocity was significantly higher at the foetal umbilical end (14.12 +/-3.18 cm/s) than at the placental end (11.93 +/-2.55 cm/s; p < 0.0001). The mean difference is 2.2 +/- 2.3 cm/s. No difference in the umbilical vein diameter was measured at both cord ends (umbilical 4.85 +/-0.9 mm, placental 4.86 +/-0.87 mm, p < 0.0001). There is no significant relationship between ΔUVVmax and the cord cross-sectional area or Wharton's jelly index.
Conclusion:
Modifications of the spatial velocity profile together with the pulsometer model could explain the maximum velocity changes that is measured in the umbilical vein along the cord. This numerical model consolidates the sonographic observations.
More Related Videos
03:33Author Spotlight: Advancing Hepatobiliary and Pancreatic Tumor Treatment with Minimally Invasive Surgical Techniques
Published on: September 27, 2024
10:25High-resolution Time-lapse Imaging and Automated Analysis of Microtubule Dynamics in Living Human Umbilical Vein Endothelial Cells
Published on: August 13, 2016
Related Concept Videos
Poiseuille's Law and Reynolds Number
Reynolds Transport Theorem
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Maximum Power Transfer
By substituting the entire circuit with...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...