Related Experiment Video
Updated: Jan 21, 2026

Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
A high resolution LC-MS targeted method for the concomitant analysis of 11 contraceptive progestins and 4 steroids
Csaba Ferenc Laszlo1, Jonathan Paz Montoya2, Marie Shamseddin1
1Swiss Institute for Experimental Cancer Research, School of Life Sciences, Ecole polytechnique fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland.
Abstract:
In the context of hormonal contraception and hormone replacement therapy (HRT), many women are exposed to exogenous hormones. Current use of hormonal contraception with combined ethinyl estradiol and different progestins bestows a breast cancer relative risk (RR) of 1.2- while combined HRT has a RR of 2. Although these exposures present an important public health issue, little is known about the effects of individual progestins on the breast and other tissues. Increasing availability of large scale biobanks, high throughput analyses and data management tools enable ever expanding, sophisticated population studies. In order to address the impact of distinct progestins on various health indicators, it is desirable to accurately quantify progestins in clinical samples. Here we have developed and validated a high resolution liquid chromatography mass spectrometry (LC-MS) targeted method for the simultaneous quantification of 11 synthetic progestins widely used in oral contraceptives, gestodene, levonorgestrel, etonogestrel, chlormadinone acetate, cyproterone acetate, drospirenone, desacetyl norgestimate, medroxyprogesterone acetate, norethindrone, dienogest, nomegestrol acetate, and 4 endogenous steroid hormones, progesterone, testosterone, androstenedione, and cortisol in blood samples. This highly specific quantitative analysis with high resolution Orbitrap technology detects and quantifies 15 compounds using their internal standard counterparts in a single 12 min LC-MS run. Sensitivity is attained by the use of the instrument in targeted selected ion monitoring mode. Lower limit of quantitation ranges from 2.4 pg/ml for drospirenone to 78.1 pg/ml for chlormadinone acetate. The method provides comprehensive progestin panel measurements with as little as 50 μl of murine or human plasma.
Related Concept Videos
Dipeptidyl Peptidase 4 Inhibitors
Piaget's Stage 4 of Cognitive Development
Abstract Reasoning and Hypothetical-Deductive Thinking
Unlike the concrete operational...
Amides to Amines: LiAlH4 Reduction
Amide reduction requires two equivalents of the reducing agent, acting as a source of hydride ions. As shown in the figure, the reaction is initiated with a nucleophilic attack by the hydride ion at the carbonyl carbon to form a tetrahedral intermediate.
Nitriles to Amines: LiAlH4 Reduction
As shown below, the mechanism involves three steps. Firstly, the hydride ion acting as a nucleophile attacks the nitrile carbon to form an anion. In the second step, a second equivalent of the hydride ion attacks the anion to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Acid Halides to Alcohols: LiAlH4 Reduction
The mechanism proceeds in three steps. First, the nucleophilic hydride ion attacks the carbonyl carbon of the acid halide to form a tetrahedral intermediate. Next, the carbonyl group is re-formed, and the halide ion departs as a leaving group, generating an aldehyde. A second nucleophilic attack by the hydride yields an alkoxide ion, which, upon protonation, gives a primary alcohol as...

