Related Experiment Video
Updated: Jan 21, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Testing a novel biotechnological passive sampler for monitoring atmospheric PAH pollution
J R Aboal1, E Concha-Graña2, F De Nicola3
1Área de Ecología, Dept. de Biología Funcional, Facultad de Biología, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain.
Abstract:
In this study we evaluated a new type of passive air sampler, the "mossphere" device, filled with a Sphagnum palustre clone. For this purpose, we compared the atmospheric levels of polyaromatic hydrocarbons (PAHs) collected using this device and those collected in conventional bulk deposition and particulate matter (PM10) samplers. All three types of samplers were exposed at 10 sites affected by different levels of pollution and located in two different climate zones. The bulk deposition/ mossphere comparison yielded a greater number of significant regressions with higher coefficients of determination than the PM10/ mossphere comparison. No significant regressions were observed for 3-ring PAHs in either comparison. The mosspheres explain ca. 50% of the variability of the concentrations of 4-, 5- and 6-ring PAHs and total PAHs detected in PM10 and ca. 70% of the corresponding concentrations detected in the bulk deposition. The use of the Sphagnum clone enables standardization of the set-up, thus making the mossphere device a good sampling tool for monitoring 4-, 5- and 6-ring and total PAHs, especially those associated with bulk deposition. The findings indicate the potential usefulness of this innovative technology for mapping PAH levels.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
09:59Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph
Published on: August 13, 2019
Related Concept Videos
Plant Breeding and Biotechnology
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...