New standards for ECG equipment
1GE Healthcare, 9900 Innovation Drive, Wauwatosa, WI 53226, USA.
Abstract:
A new standard for electrocardiographic (ECG) medical equipment is currently in development by the ISO/IEC Joint Work Group 22 (JWG22) and is entitled "80601, part 2-86: Particular requirements for the basic safety and essential performance of electrocardiographs, including diagnostic equipment, monitoring equipment, ambulatory equipment, electrodes, cables, and leadwires". This new standard will replace the current set of IEC particular standards that pertain to ECG equipment, namely, 60601-2-25 (diagnostic electrocardiographs), 60601-2-27 (ECG patient monitors), and 60601-2-47 (Ambulatory ECG) and also incorporates AAMI standards EC12 (disposable electrodes), EC53 (ECG cables and leadwires), and EC57 (arrhythmia analysis performance reporting). This new ECG device standard will define basic safety and essential performance requirements and compliance testing methods for all types of ECG devices including both legacy types of ECG devices as well as new types of ECG devices. In addition to the general requirements, specific requirements and testing methods will apply exclusively to devices claiming to be used as a diagnostic electrocardiograph, an ECG patient monitor, and or an ambulatory ECG device. The primary goal of the work to develop this new ECG standard is to combine and harmonize the content of the existing set of 6 ECG standards. In addition, because many of these standards are quite mature, this work provides an opportunity to update the content to align requirements and testing methods with changes in ECG technology as well as changes in the clinical use of ECG and the emergence of new types of ECG devices. The changes under consideration and the progress of this work by ISO/IEC JWG22 is reviewed. Specific updates are highlighted, including requirements for defibrillation recovery, changes for ECG filtering technology, and changes to address advancement in implanted pacing technology.
Related Concept Videos
Leveling Equipment
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Personal Protective Equipment
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...