Related Experiment Video
Updated: Jan 21, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Venous-to-arterial pCO2 difference in high-risk surgical patients
Pierre Huette1, Omar Ellouze2, Osama Abou-Arab1
1Anaesthesiology and Critical Care Department, Cardiothoracic ICU, Amiens University Hospital, Amiens, France.
Abstract:
Alteration of tissue perfusion is a main contributor to organ dysfunction in high-risk surgical patients. The difference between venous carbon dioxide and arterial carbon dioxide pressure (pCO2 gap) has been described as a parameter reflecting tissue hypoperfusion in critically ill patients who are insufficiently resuscitated. The pCO2 gap/CavO2 ratio has also been described as an indicator of the respiratory quotient, thus the relationship between DO2 and VO2. Most of the knowledge about the pCO2 gap and the pCO2 gap/CavO2 ratio has come from studies in the literature on animal models or intensive care unit (ICU) patients. To date, publications pertaining to the operative setting are sparse. In the present review, we will first discuss the physiological background of the pCO2 gap and CO2-O2 derived parameters used in the operating room. Few studies have focused on the clinical relevance of the pCO2 gap in high-risk non-cardiac surgical patients. Prospective observational studies with a small sample size and retrospective studies have shown that the pCO2 gap may be a useful complementary tool to identify patients who remain insufficiently optimized hemodynamically. In a few studies, a high pCO2 gap was associated with postoperative complications following non-cardiac high-risk surgery. Results of observational studies conducted in patients undergoing cardiac surgery are contradictory. We focused on the divergence between non-cardiac surgery, cardiac surgery, and septic critically ill patients. When analyzing the literature, we can find some explanations for the discrepancies in the published results between cardiac and non-cardiac surgery. Finally, we will discuss the clinical utility of the pCO2 gap in high-risk surgical patients.
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Relative Risk
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...

