Background:
Venous thromboembolism includes deep vein thrombosis (DVT) and pulmonary embolism. Compression ultrasonography is the most common way to evaluate DVT and is typically performed by sonographers and interpreted by radiologists. Yet there is evidence that ultrasound examinations can be safely and accurately performed by clinicians at the bedside.
Objective:
To measure the operating characteristics of hospital medicine providers performing point-of-care ultrasound (POCUS) for evaluation of DVT.
Design:
This is a prospective cohort study enrolling a convenience sample of patients. Hospital medicine providers performed POCUS for DVT and the results were compared with the corresponding formal vascular study (FVS) interpreted by radiologists.
Participants:
Hospitalized non-ICU patients at four tertiary care hospitals for whom a DVT ultrasound was ordered.
Main Measures:
The primary outcomes were the sensitivity, specificity, and predictive values of the POCUS compression ultrasound compared with a FVS. The secondary outcome was the elapsed time between order and the POCUS study compared with the time the FVS was ordered to when the formal radiology report was finalized.
Key Results:
One hundred twenty-five limbs from 73 patients were scanned. The prevalence of DVT was 6.4% (8/125). The sensitivity of POCUS for DVT was 100% (95% CI 74-100%) and specificity was 95.8% (95% CI 91-98%) with a positive predictive value of 61.5% (95% CI 35-84%) and a negative predictive value of 100% (95% CI 98-100%). The median time from order to POCUS completion was 5.8 h versus 11.5 h median time from order until the radiology report was finalized (p = 0.001).
Conclusion:
Hospital medicine providers can perform compression-only POCUS for DVT on inpatients with accuracy similar to other specialties and settings, with results available sooner than radiology. The observed prevalence of DVT was lower than expected. POCUS may be reliable in excluding DVT but further study is required to determine how to incorporate a positive POCUS DVT result into clinical practice.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
06:45Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Interdisciplinary Care: The Health Care Team-I
Physicians
The physician's primary responsibility is to diagnose illness and direct the medical or surgical treatment of the condition. The authority to admit patients to a healthcare agency or institution and practice care within that setting is granted to physicians by the healthcare agency or institution...