Related Experiment Video
Updated: Jan 21, 2026

09:15
In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
1.2K
A modified implantation technique for temporary right ventricular assist device: Enabling ambulation and less
Daniel Rinewalt1, Yasuhiro Shudo1, John W MacArthur1
1Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, California.
Journal of Cardiac Surgery
|August 8, 2019
Summary
A novel temporary right ventricular assist device (RVAD) technique allows early patient mobilization and less invasive removal. This approach avoids resternotomy, improving recovery after biventricular support.
Area of Science:
- Cardiology
- Cardiovascular Surgery
- Medical Devices
Background:
- Right ventricular assist devices (RVADs) are crucial for supporting patients with right heart failure.
- Current RVAD management can limit patient mobility and complicate removal procedures.
- Biventricular support often necessitates complex management strategies.
Observation:
- A unique temporary RVAD implantation technique was developed.
- This technique facilitates early patient mobilization.
- It also allows for less invasive RVAD removal.
Findings:
- The described RVAD implantation technique enables early mobilization, even during biventricular support.
- Subsequent RVAD removal is less invasive, avoiding the need for resternotomy.
- This method streamlines the recovery process for patients requiring RVAD support.
Implications:
- This technique has the potential to improve patient outcomes and reduce healthcare costs.
- It offers a less invasive alternative for RVAD management.
- Further research may validate this approach in broader clinical settings.
Related Concept Videos
Tracheostomy Decannulation
1.3K
Tracheostomy decannulation is a significant milestone in the liberation of mechanically ventilated patients. Despite its importance, there is no universally accepted protocol for this procedure. This demands an evidence-based, individualized approach.
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
1.3K
Modified Boxplots
10.8K
A standard box and whisker plot informs us about the spread of the data in a given sample. One can identify the minimum value, maximum value, first quartile value, second quartile or median value, and third quartile.
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
10.8K
Mnemonic Devices
404
Mnemonic devices are cognitive tools that facilitate memory retention by linking new information to familiar patterns or organizational strategies. These techniques are beneficial for remembering complex or lengthy sets of information by simplifying and structuring them in easily retrievable ways.
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
404
Non-ohmic Devices
1.5K
In most substances, the current flow is proportional to the voltage applied to it. A simple relationship between the values of current, voltage, and resistance is known as Ohm's law. Nonohmic devices do not exhibit a linear relationship between voltage and current. One such device is the semiconducting circuit element known as a diode. A diode is a circuit device that allows current flow in only one direction.
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
1.5K
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
488
Arrhythmia is a condition characterized by an irregular heart rhythm, with ECG changes that differ based on its origin and nature. The types of arrhythmias discussed below include atrial, junctional, and ventricular arrhythmias.Atrial ArrhythmiasPremature Atrial Complexes (PACs): PACs are early atrial beats caused by stress, caffeine, alcohol, electrolyte imbalances, hypoxia, hyperthyroidism, or certain medications (e.g., bronchodilators and decongestants). The ECG shows early P waves with an...
488
Antiasthma Drugs: Leukotriene Modifiers
1.8K
Leukotriene modifiers, or cysteinyl leukotriene receptor antagonists, are medications used to manage chronic asthma. These agents target specific inflammatory mediators produced during arachidonic acid metabolism, an essential process in generating inflammation in the body.
Leukotriene modifiers work through two distinct mechanisms:
Leukotriene modifiers work through two distinct mechanisms: