Related Experiment Video
Updated: Jan 21, 2026

The Establishment of a Murine Mandibular Molar Extraction Socket Healing Model
Published on: January 13, 2023
Immediate Loading of Unsplinted Implant Retained Mandibular Overdenture: A Randomized Controlled Clinical Study
Ahmad Kutkut1, Mohamed Rezk2, Dominique Zephyr3
1Division of Restorative Dentistry, College of Dentistry, University of Kentucky, Lexington, Ky.
Abstract:
This clinical study aimed to clinically and radiographically compare the implant survival rate and peri-implant tissue response between immediate and delayed loading protocols for unsplinted implant retained mandibular overdentures. Twenty patients were enrolled to participate in this study. Each subject was randomly assigned to 1 of 2 treatment groups: test group patients' implants (n = 10), which were immediately loaded, and control group patients' implants (n = 10), which were conventionally loaded. Locator abutments were torqued to 15 Ncm at delivery. Attachments were picked up intraorally immediately after implant placement for the test group and at 3 months for the control group, and 3-lb retention inserts were placed. Marginal bone levels based on cone beam computed tomography fixed reference points were recorded at baseline and 12 months. Modified plaque index, gingival index, and implant stability quotients were recorded at baseline, 3 months, and 12 months. After 12 months, implant survival rate was 100% in both groups. Marginal bone levels, keratinized mucosa, modified plaque index, and gingival index were significantly different among the groups at 3- and 12-month intervals, whereas no significant differences were found in implant stability quotients between the groups. The fact that implant survival rate was 100% in both treatment groups suggests that, within the limitations of this study, immediate loading protocol for unsplinted implant retained mandibular complete overdenture is as predictable, safe, and successful as the delayed loading protocol. Implementing the immediate loading protocol for mandibular implant retained overdentures could shorten treatment time, which could lead to better patient's satisfaction.
Related Concept Videos
Load-frequency control
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...

