Related Experiment Video
Updated: Jan 21, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Are Accelerometer-based Functional Outcome Assessments Feasible and Valid After Treatment for Lower Extremity
Sherron Furtado1, Alan Godfrey2, Silvia Del Din3
1S. Furtado, North of England Bone and Soft Tissue Tumor Service, Department of Orthopaedics, Freeman Hospital, Newcastle Upon Tyne, United Kingdom.
Background:
Aspects of physical functioning, including balance and gait, are affected after surgery for lower limb musculoskeletal tumors. These are not routinely measured but likely are related to how well patients function after resection or amputation for a bone or soft tissue sarcoma. Small, inexpensive portable accelerometers are available that might be clinically useful to assess balance and gait in these patients, but they have not been well studied.
Questions/Purposes:
In patients treated for lower extremity musculoskeletal tumors, we asked: (1) Are accelerometer-based body-worn monitor assessments of balance, gait, and timed up-and-go tests (TUG) feasible and acceptable? (2) Do these accelerometer-based body-worn monitor assessments produce clinically useful data (face validity), distinguish between patients and controls (discriminant validity), reflect findings obtained using existing clinical measures (convergent validity) and standard manual techniques in clinic (concurrent validity)?
Methods:
This was a prospective cross-sectional study. Out of 97 patients approached, 34 adult patients treated for tumors in the femur/thigh (19), pelvis/hip (3), tibia/leg (9), or ankle/foot (3) were included in this study. Twenty-seven had limb-sparing surgery and seven underwent amputation. Patients performed standard activities while wearing a body-worn monitor on the lower back, including standing, walking, and TUG tests. Summary measures of balance (area [ellipsis], magnitude [root mean square {RMS}], jerkiness [jerk], frequency of postural sway below which 95% of power of acceleration power spectrum is observed [f95 of postural sway]), gait [temporal outcomes, step length and velocity], and TUG time were derived. Body-worn monitor assessments were evaluated for feasibility by investigating data loss and patient-reported acceptability and comfort. In addition, outcomes in patients were compared with datasets of healthy participants collected in parallel studies using identical methods as in this study to assess discriminant validity. Body-worn monitor assessments were also investigated for their relationships with routine clinical scales (the Musculoskeletal Tumour Society Scoring system [MSTS], the Toronto Extremity Salvage Score [TESS], and the Quality of life-Cancer survivors [QoL-CS)] to assess convergent validity and their agreement with standard manual techniques (video and stopwatch) to assess concurrent validity.
Results:
Although this was a small patient group, there were initial indications that body-worn monitor assessments were well-tolerated, feasible to perform, acceptable to patients who responded (95% [19 of 20] of patients found the body-worn monitor acceptable and comfortable and 85% [17 of 20] found it user-friendly), and produced clinically useful data comparable with the evidence. Balance and gait measures distinguished patients and controls (discriminant validity), for instance balance outcome (ellipsis) in patients (0.0475 m/s [95% confidence interval 0.0251 to 0.0810]) was affected compared with controls (0.0007 m/s [95% CI 0.0003 to 0.0502]; p = 0.001). Similarly gait outcome (step time) was affected in patients (0.483 seconds [95% CI 0.451 to 0.512]) compared with controls (0.541 seconds [95% CI 0.496 to 0.573]; p < 0.001). Moreover, body-worn monitor assessments showed relationships with existing clinical scales (convergent validity), for instance ellipsis with MSTS (r = -0.393; p = 0.024). Similarly, manual techniques showed excellent agreement with body-worn monitor assessments (concurrent validity), for instance stopwatch time 22.28 +/- 6.93 seconds with iTUG time 21.18 +/- 6.23 seconds (intraclass correlation coefficient agreement = 0.933; p < 0.001). P < 0.05 was considered statistically significant.
Conclusions:
Although we had a small, heterogeneous patient population, this pilot study suggests that body-worn monitors might be useful clinically to quantify physical functioning in patients treated for lower extremity tumors. Balance and gait relate to disability and quality of life. These measurements could provide clinicians with useful novel information on balance and gait, which in turn could guide rehabilitation strategies.
Level Of Evidence:
Level III, diagnostic study.
Related Concept Videos
Reliability and Validity
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Absolute and Local Extreme Values
Rous Sarcoma Virus (RSV) and Cancer
RSV is a retrovirus that contains two copies of a plus-strand RNA genome. Its genome consists of four main open...
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...