Related Experiment Video
Updated: Jan 21, 2026

Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
Published on: March 14, 2018
Are we crying Wolff? 3D printed replicas of trabecular bone structure demonstrate higher stiffness and strength
Zach Wood1, Lisa Lynn1, Jack T Nguyen1
1Department of Biology, Winthrop University, Rock Hill, SC 29733, USA.
Abstract:
Roux's principle of bone functional adaptation postulates that bone tissue, and particularly trabecular bone tissue, responds to mechanical stimuli by adjusting (modeling) its architecture accordingly. Hence, it predicts that the new modeled trabecular structure is mechanically improved (stiffer and stronger) in line with the habitual in vivo loading direction. While previous studies found indirect evidence to support this theory, direct support was so far unattainable. This is attributed to the fact that each trabecular bone is unique, and that trabecular bone tissue tends to be damaged during mechanical testing. Consequently, a unique modeled trabecular structure can be mechanically tested only along one direction and a comparison to other directions for that specific structure is impossible. To address this issue, we have 3D printed 10 replicas of a trabecular structure from a sheep talus cropped along the 3 principal axes of the bone and in line with the principal direction of loading (denoted on-axis model). Next, we have rotated the same cropped trabecular structure in increments of 10° up to 90° to the bone principal direction of loading (denoted off-axis models) and printed 10 replicas of each off-axis model. Finally, all on-axis and off-axis 3D printed replicas were loaded in compression until failure and trabecular structure stiffness and strength were calculated. Contrary to our prediction, and conflicting with Roux's principle of bone functional adaptation, we found that a trabecular structure loaded off-axis tended to have higher stiffness and strength values when compared to the same trabecular structure loaded on-axis. These unexpected results may not disprove Roux's principle of bone functional adaptation, but they do imply that trabecular bone adaptation may serve additional purposes than simply optimizing bone structure to one principal loading scenario and this suggests that we still don't fully understand bone modeling in its entirety.
Related Concept Videos
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Bone Structure
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Hypothalamic-Pituitary Axis
Aldehydes and Ketones to Alkanes: Wolff–Kishner Reduction