Related Experiment Video
Updated: Jan 21, 2026

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
Published on: January 12, 2022
Measurement of Oral Epithelial Thickness by Optical Coherence Tomography
Dario Di Stasio1, Dorina Lauritano2, Hasan Iquebal3
1Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania-Luigi Vanvitelli, 80138 Naples, Italy.
Abstract:
Optical coherence tomography (OCT) is a real-time, in-situ, non-invasive imaging device that is able to perform a cross-sectional evaluation of tissue microstructure based on the specific intensity of back-scattered and reflected light. The aim of the present study was to define normal values of epithelial thickness within the oral cavity. OCT measurements of epithelial thickness were performed in 28 healthy patients at six different locations within the oral cavity. Image analysis was performed using Image J 1.52 software. The healthy epithelium has a mean thickness of 335.59 ± 150.73 µm. According to its location within the oral cavity, the epithelium showed highest values in the region of the buccal mucosa (659.79 µm) and the thinnest one was observed in the mouth's floor (100.07 µm). OCT has been shown to be useful for the evaluation of oral mucosa in vivo and in real time. Our study provides reference values for the epithelial thickness of multiple sites within the oral cavity. Knowledge of the thickness values of healthy mucosa is, therefore, of fundamental importance.
More Related Videos
Related Concept Videos
Oral Cavity
Teeth: The teeth are the hardest structures in our bodies. Humans have two sets of teeth throughout their lifetime: deciduous (baby) teeth and permanent teeth. Each tooth consists of several parts: the crown (visible part), the root (embedded in the jaw), enamel (hard outer...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Oral Hypoglycemic Agents: Glinides
Psychosexual Stages of Personality: Oral
Weaning, typically occurring...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Oral Hypoglycemic Agents: Sulfonylureas

