Validity and reliability of serratus anterior hand held dynamometry
Jos IJspeert1, Hans C J W Kerstens2,3, Renske M J Janssen4
1Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, the Netherlands. jos.ijspeert@radboudumc.nl.
Background:
Strength testing of the serratus anterior muscle with hand held dynamometry (HDD) in supine subjects has low reproducibility, and is influenced by compensatory activity of other muscles like the pectoralis major and upper trapezius. Previously, two manual maximum voluntary isometric contraction tests of the serratus anterior muscle were reported that recruited optimal surface electromyography (sEMG) activity in a sitting position. We adapted three manual muscle tests to make them suitable for HHD and investigated their validity and reliability.
Methods:
Twenty-one healthy adults were examined by two assessors in one supine and two seated positions. Each test was repeated twice. Construct validity was determined by evaluating force production (assessed with HHD) in relation to sEMG of the serratus anterior, upper trapezius and pectoralis major muscles, comparing the three test positions. Intra- and interrater reliability were determined by calculating intra-class correlation coefficients (ICC) smallest detectable change (SDC) and standard error of measurement (SEM).
Results:
Serratus anterior muscle sEMG activity was most isolated in a seated position with the humerus in 90° anteflexion in the scapular plane. This resulted in the lowest measured force levels in this position with a mean force of 296 N (SEM 15.8 N). Intrarater reliability yielded an ICC of 0.658 (95% CI 0.325; 0.846) and an interrater reliability of 0.277 (95% CI -0.089;0.605). SDC was 127 Newton, SEM 45.8 Newton.
Conclusion:
The results indicate that validity for strength testing of the serratus anterior muscle is optimal with subjects in a seated position and the shoulder flexed at 90° in the scapular plane. Intrarater reliability is moderate and interrater reliability of this procedure is poor. However the high SDC values make it difficult to use the measurement in repeated measurements.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
09:35Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Related Concept Videos
Reliability and Validity
Hand hygiene
Hand washing...
Distribution Reliability and Automation
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include:
Muscles of the Anterior Neck