Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Utilizing Venoplasty Balloon Model in Rodents to Simulate Surgical Interventions for Deep Veins
Published on: May 24, 2024
Prophylactic inferior vena cava filters for operative pelvic fractures: a twelve year experience
Wayne B Cohen-Levy1, Jin Liu2, Milan Sen3
1Department of Orthopaedics, Jackson Memorial Hospital, University of Miami, PO Box 016960 (D27), Miami, FL, 33101, USA. wayne.cohenlevy@jhsmiami.org.
Introduction:
Conflicting evidence exists regarding the role of inferior vena cava filters (IVCFs) in the prevention of pulmonary embolism. The aim of this study was to review an institutional policy of prophylactic IVCF placement in all operative pelvic and acetabular fractures as a means of preventing PE by comparing it to a historical prepolicy period of significantly less aggressive IVCF placement.
Methods:
The trauma registry of a single level 1 trauma center was retrospectively queried for all pelvic or acetabular fractures for the prepolicy and intervention periods as defined as January 2003-December 2008 and January 2009-December 2014, respectively-yielding 231 patients for analysis. The primary and secondary outcomes measured were the incidence of PE and deep vein thrombosis.
Results:
The rate of prophylactic IVCF insertion significantly increased during the study period (p < 0.001). The incidence of pulmonary embolism (1.8% vs. 5.1%, p = 0.351) and DVT (19.3% vs. 10.3%, p = 0.231) were not significantly different when comparing the prepolicy and intervention cohorts. In patients with operative fractures, a nonsignificant trend of increasing incidence of DVTs was appreciated in patients with a prophylactic IVCF versus those without prophylactic IVCF (13 vs. 2, p = 0.222).
Discussion:
A policy of increased use of prophylactic IVCFs in patients with operative pelvic and acetabular fractures failed to reduce the incidence of PE or DVT. In contrast, several case reports and institutional series have published several risks associated with IVCF placement including failure to retrieve temporary IVCF.
Conclusion:
The benefit of prophylactic IVCF in this patient population is unclear.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Muscles of the Pelvic Floor and Perineum
Perineal Layer
The perineum is a diamond-shaped area below the pelvic diaphragm, divided into an anterior urogenital triangle that contains the external genitals and a posterior anal triangle housing the anus. The urogenital...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
The Stanford Prison Experiment
Operational Amplifiers

