Linear measurements of sinus floor elevation based on voxel-based superimposition of cone beam computed tomography
Jie Huang1, Jiahui Hu1, Rongchun Luo1
1Department of Oral Implantology, School and Hospital of Stomatology, Tongji University; Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China.
Background:
Postsurgical evaluation of sinus floor elevation regularly involves linear measurements of the elevated volumes in the cone beam computed tomography (CBCT) images. The accuracy of measurements could be compromised due to ill-defined sinus floor outline if implants are placed simultaneously.
Purpose:
The aim was to examine a CBCT superimposition method to improve the measurement accuracy.
Materials And Methods:
Twenty patients who received transalveolar sinus floor elevation with immediate implantation were enrolled. CBCTs before and after surgery were transformed into digital imaging and communications in medicine format and imported into the Dolphin Imaging software. Voxel-based superimposition was automated to merge the files. In the superimposed image, parameters including alveolar bone height, protruded implant length, and total elevated height were measured. The superimposition and measurements were performed independently by two examiners and in two timepoints with 1-week time interval. We used intraclass correlation coefficient (ICC) to analyze the interexaminer and intraexaminer agreements.
Results:
Of measured parameters, the mean of difference between two timepoints ranged from 0.18 to 0.26 mm by examiner 1, and from 0.16 to 0.20 mm by examiner 2. ICCs were equal or greater than 0.98, indicating perfect intraexaminer agreement. For interexaminer reliability, the largest mean of difference was 0.27 mm in measuring alveolar bone height between two examiners. ICCs were greater than 0.98, showing perfect interexaminer agreement.
Conclusions:
The voxel-based superimposition of pre- and post-surgical CBCT images with Dolphin Imaging is an effective and reliable way for linear measurements so as to assess the surgical outcome. There is minimal effect on reproducibility of measured data by different timepoints or performers.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Muscles of the Pelvic Floor and Perineum
Perineal Layer
The perineum is a diamond-shaped area below the pelvic diaphragm, divided into an anterior urogenital triangle that contains the external genitals and a posterior anal triangle housing the anus. The urogenital...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Base Excision Repair
The first step of...