Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Repetitive Transcranial Magnetic Stimulation Combined with Movement Observation in Cerebral Palsy
Published on: August 9, 2024
Should Proximal Femoral Implants be Removed Prophylactically or Reactively in Children With Cerebral Palsy?
Walter H Truong1,2, Susan A Novotny1, Tom F Novacheck1,2
1Gillette Children's Specialty Healthcare, Department of Orthopaedic Surgery, University of Minnesota, Saint Paul.
Insights
A reactive approach to removing proximal femoral implants in children with cerebral palsy (CP) is effective, with 80% avoiding surgery. While unplanned removals were higher, complication rates were similar, suggesting a reactive strategy is viable for implant removal in CP patients.
Area of Science:
- Orthopedic surgery
- Pediatric orthopedics
- Cerebral palsy management
Background:
- Proximal femoral osteotomies in children with cerebral palsy (CP) commonly utilize implants for stabilization.
- Routine prophylactic removal of these implants is standard practice, aiming to prevent complications like infection, fracture, or pain.
- Limited evidence supports a prophylactic strategy over a reactive, symptom-based approach for implant removal.
Purpose of the Study:
- To compare the outcomes of prophylactic versus reactive strategies for proximal femoral implant removal in pediatric CP patients.
- To evaluate complication rates and the necessity of surgery associated with each removal approach.
Main Methods:
- An intention-to-treat model compared two institutions with prophylactic (within ~1 year) and reactive (symptom-driven) implant removal protocols.
- Included patients with CP, femoral implants placed before age 16, and at least 2-year follow-up.
- Data collected included demographics, surgical details, reasons for removal, and complications; analyzed using chi-squared and t-tests.
Main Results:
- 621 patients (302 prophylactic, 319 reactive) were followed for an average of 6 years.
- 95% of implants were removed prophylactically (average 1.2 years), versus 20% reactively (average 4.2 years).
- The reactive group had a higher rate of unplanned removal due to fracture/infection (4.7% vs. 0.7%, P=0.002), but no difference in removal complications (3.1% vs. 1.7%, P=0.616).
Conclusions:
- Eighty percent of patients in the reactive group avoided surgery, with similar complication rates during removal compared to the prophylactic group.
- A reactive approach necessitates removing implants from 25 patients to avoid one additional complication.
- This study provides support for a reactive strategy for proximal femoral implant removal in children with CP.
Background:
Implants are commonly used to stabilize proximal femoral osteotomies in children with cerebral palsy (CP). Removal of implants is common practice and believed to avoid infection, fracture, or pain that might be associated with retained hardware. There is little evidence to support a prophylactic strategy over a reactive approach based on symptoms. The aim of this study was to compare the outcomes of prophylactic and reactive approaches to removal of proximal femoral implants in children with CP.
Methods:
An intention-to-treat model was used to compare 2 institutions that followed a prophylactic (within ∼1 y) and reactive (following complication/symptoms) approach to hardware removal, respectively. Patients with CP who had femoral implants placed at or before age 16, and had ≥2-year postsurgical follow-up were included. Demographics, surgical details, reasons for removal, and complications were recorded. χ and t tests were used.
Results:
Six hundred twenty-one patients (prophylactic=302, reactive=319) were followed for an average of 6 years (range, 2 to 17 y). Two hundred eighty-seven (95%) implants were removed in the prophylactic group at 1.2 years. In the reactive group, 64 (20%) implants were removed at an average of 4.2 years. Reasons for removal included pain; infection; fracture; or for repeat reconstruction. The rate of unplanned removals due to fracture or infection was higher in the reactive group (4.7% vs. 0.7%, P=0.002), but there was no difference in the rate of complications during/after removal between the 2 groups (1.7% vs. 3.1%; P=0.616). No specific risk factor associated with unplanned removal could be identified; but children under 8 years old seemed more likely to undergo later removal (odds ratio 1.98; 95% confidence interval, 0.99-3.99).
Conclusions:
Eighty percent of patients in the reactive removal strategy avoided surgery. This group did have a 4% higher rate of fracture or infection necessitating unplanned removal but these were successfully treated at time of removal with no difference in complication rates associated with removal between both groups. One would need to remove implants from 25 patients to avoid 1 additional complication, providing some support for a reactive approach to removal of proximal femoral implants in this population.
Level Of Evidence:
Level III-therapeutic.
More Related Videos
08:24Author Spotlight: Exploring the Potential of Massage Therapy in Cerebral Palsy Using Animal Models
Published on: August 11, 2023
08:26Event-related Potentials During Target-response Tasks to Study Cognitive Processes of Upper Limb Use in Children with Unilateral Cerebral Palsy
Published on: January 11, 2016
Related Concept Videos
Cross-reactivity
Reactivity of Enols
Factors Influencing Attraction I: Proximity
Reactivity of Enolate Ions
Radical Reactivity: Overview
Drug Dosing: Infants and Children